How can I turn off the zeiss Humphrey? only from the shut down button or there is a function from the software?

This is a brand name, not a specific device and model. That said, here is a page describing mode switch in the setup screen using the touch screen for a specific device. I assume a touch screen would have an icon for turning a device off. Zeiss HUMPHREY 720i User Manual System Setup
6/7/2018 10:20:13 AM • Zeiss Science &... • 1,063 views • 0 helpful votes
0helpful
1answer

Screen is black

It sounds like the backlight of the LCD display is out. The Image is still being displayed there is just no light to illuminate the image. Try shining a flashlight on it (Put the light right against the screen) and see if you can see what's on the screen. The display is fairly easy to install but I do not know where you can purchase one directly.
6/9/2017 1:15:03 PM • Zeiss Gdx/vcc... • 2,227 views • 0 helpful votes
0helpful
1answer

Humphrey ATLAS topographer- turning joystick no longer raises or lowers topographer

You need to replace the belt that drives the elevator gear from the joystick. If you need help with this feel free to call or email [email protected] 815.325.5838
3/24/2016 9:11:40 PM • Zeiss Humphrey... • 834 views • 0 helpful votes
0helpful
1answer

Why no blind spot dectected

The two most common problems when trying to find a blind spot are: A.) Forgetting to patch the eye, and B.) Choosing the correct eye in the machine itself.
12/3/2015 4:08:23 PM • Zeiss Humphrey... • 1,040 views • 0 helpful votes
0helpful
2answers

Manual for Humphrey Acuitus 5015.2552

i have the manual and the belt, pls contact at [email protected] marcelo
9/30/2015 5:19:18 PM • Zeiss Humphrey... • 1,266 views • 0 helpful votes
0helpful
1answer

My fan will not turn on. What part do I need to order

I assume you are talking about your electric fan they could be 2 reason your fan relay need to change or temp sensor i suggest start with changing your relay
8/2/2015 7:07:12 PM • Zeiss COLPOSCOPE... • 828 views • 0 helpful votes
1helpful
1answer

Hello Repair. I'm trying to fix some motherboards for the Acuitus 5015. Do you fix them ? Do you sell any? Or do you know where I can purchase them? Please email me at [email protected]

These equipments use a sbc492 by Aaeon motherboard, and usually they shows a message like "Cmos battery Low".These motherboards use an RTC M48T86PCI with a internal lithyum battery, and just replace that component.Other problems may occur, like damaged slots, and or oxidation, but generally the 486 architecture is a huge way to work,Only clean change the memory(dimm 128 x 100mh)and enjoy.A simple way is a replacement with a new one by Intel, still easy to find in some inventorys, i have many in USA who can suply. hope to solved
2/22/2015 8:08:46 PM • Zeiss Humphrey... • 1,458 views • 1 helpful votes
0helpful
1answer
0helpful
1answer

How do I hook my external laser printer to my humphrey 740?

In the user manual they list some compatible printers that have a 25 pin parallel connector. We use Lexmark Optra E312L with good results. Once you hook it up, you have to go into one of the setup menus to port it over. The user guide tells the procedure.
10/8/2014 3:27:51 PM • Zeiss Humphrey... • 1,199 views • 0 helpful votes
0helpful
1answer

How do I fix the pointer on the touchscreen to be where you touch

You sjould press the patient button and the same time turn it the instrument on keep in button press until you see in tje display the calibration message of the touchscreen
10/3/2014 3:00:46 PM • Zeiss Humphrey... • 532 views • 0 helpful votes
1helpful
1answer

How do I clean the Zeiss Cirrus HD OCT Model 400, 4000 between Patients?

Just with alcohol and cotton, nothing else, you should only clean the head rest and the chinrest
10/17/2014 1:06:18 AM • Zeiss Cirrus... • 346 views • 1 helpful votes
0helpful
1answer

Ziess /Humphrey atlas 990 servicing

You neef begin by the lowes part. You sjould rest the instrument on tje left side to get the botton screws.
In orther to take the covers you sjoul take away first the chinrest
10/3/2014 9:01:07 PM • Zeiss Humphrey... • 481 views • 0 helpful votes
0helpful
1answer

CAN THE LIGHT BE TURNED ON IN THE ROOM WHERE THE TESTING IS DONE?

Yes it affect all tje instrument calibration when it is turn on, and when you have patient test the result is afected because the patien has light for the bavk and he is not able to see all the diferents type of lights
9/18/2014 6:32:23 PM • Zeiss Humphrey... • 354 views • 0 helpful votes
0helpful
1answer

How can I fix my screen ,will not show anything on the field analyzer 740i? Help please

Did you move the brighness control. It is on the right side of the equipment. If not, it could be the video board inside of the equipment
8/5/2014 5:06:32 PM • Zeiss Humphrey... • 1,230 views • 0 helpful votes
0helpful
1answer

Why does humphrey visual field analyzer beep when i turn it on?

The trouble is with the CPU. It needs to be replaced
8/4/2014 9:12:19 PM • Zeiss Humphrey... • 1,198 views • 0 helpful votes
Not finding what you are looking for?
Zeiss Logo

56 questions posted

Ask a Question

Usually answered in minutes!

Top Zeiss Science & Laboratory Experts

Aron

Level 3 Expert

2586 Answers

Don A
Don A

Level 3 Expert

4495 Answers

Eliuska Castillo

Level 1 Expert

18 Answers

Are you a Zeiss Science and Laboratory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...