Honda Electrical Supplies - Recent Questions, Troubleshooting & Support

0helpful
1answer

How to remove tank on a honda eg5000cl generator

This is reasonably easy to do. Does the Generator run? Start the generator as it's running turn the fuel Petcock to the Off position. The generator should stall and stop running. This helps safely empty the fuel line and carburettor between the tank and the engine. Disconnect the fuel line from the petcock tap and plug the ends to stop dirt getting in. On each corner of the tank itself there should be a bolt going through the ribbed edge and a rubber spacer. remove these 4 bolts and the tank should lift up and out. On some generators you might have to remove some trim panels to make it easier. Refitting is the exact opposite of this.
1/28/2024 5:34:28 PM • Honda Electrical... • Answered on Jan 28, 2024
0helpful
1answer

Honda2200 generator, bluetooth

Provides information about the generator's status, performance, and reminders. The app also allows you to turn the generator on and off remotely, monitor fuel levels, and set the Eco-Throttle mode. Connect Your Honda 2200i to Bluetooth - YouTube honda 2200 bluetooth pairing - Search (bing.com)
1/21/2024 10:49:37 PM • Honda Electrical... • Answered on Jan 21, 2024
0helpful
1answer

2009 Honda BF50 Marine Outboard. It takes about 10 minutes of driving before it starts to run normally. Adding gas to the drive means engine choking.

Question edited for clarity, 'year make model (what it is)'. Question moved from Honda Cars. https://www.seaseamarine.com/products/honda-marine-mid-size-outboard-bf50 In the same way as cars are fuel injected and completely electronically driven, you have to take them to a dealer and they put them on a scan tool computer. That diagnoses all the systems and tells where the problem is. If the problem clears after 10 minutes and warming up, it is likely a fuel injector issue. Check the spark plugs and leads. Or the choke is sticking and then comes unstuck. I have never used the choke on my Mercury 60. https://www.google.com/search?q=honda+50bf+run+rough+for+10+minutes The guy in the video is Kyle Noseworthy, and he is also a great knifemaker. He sharpened 4 knives for me. Not sure if the video will help, but it is the only one on that engine.
11/10/2023 6:00:02 PM • Honda outboard • Answered on Nov 10, 2023
0helpful
1answer

Free manual 7000/8750 black max manual

Need parts for maintnance
10/22/2023 2:55:18 PM • Honda Black Max... • Answered on Oct 22, 2023
0helpful
2answers

Hi does anyone know or have a contact for parts for a Honda eg550 generator

You'll need allot of info from your unit...but ck here...https://www.megazip.net/zapchasti-dlya-generatorov/honda/eg550-12536/eg550-25744or try here...copy and paste.https://www.megazip.net/zapchasti-dlya-generatorov/honda/eg550-12536/eg550-25744/eg550-770365/fuel-tank-eg550-eg650-13411092
7/14/2023 10:02:16 PM • Honda Electrical... • Answered on Jul 14, 2023
0helpful
1answer

Honda EM6500S Generator. What is the inlet valve and exhaust valve and cylinder head settings on the EM6500LPG Generator please?

Question edited for a lot more clarity. Question moved to model category. Page 93 of the manual refers

Owner's Manual - GENERATOR EM5000SX/EM6500SX

Honda https://cdn.powerequipment.honda.com > manuals PDF This owner's manual is considered a permanent part of the generator and should remain with the generator if resold. The information and specifications included ...

Owner's Manual - GENERATOR EM5000SX/EM6500SX

Honda https://cdn.powerequipment.honda.com > manuals PDF This owner's manual is considered a permanent part of the generator and should remain with the generator if resold. The information and specifications included ...

Honda Small Engine Intake & Exhaust Valve Clearances

Steve's Small Engine Saloon https://www.stevessmallenginesaloon.com > hon... PDF Model Series. Intake Valve Clearance. Exhaust Valve Clearance. GX640. 0.10-0.14mm ( 0.004-0.006in ). 0.18-0.22mm ( 0.007-0.009in ). GX100. 0.15 +/- 0.04mm.
7/14/2023 3:49:24 PM • Honda... • Answered on Jul 14, 2023
0helpful
2answers

No Spark On Ems 4500 Honda Generator

Check oil alert switch, ignition switch and connections.
5/17/2023 9:10:35 AM • Honda Electrical... • Answered on May 17, 2023
0helpful
1answer

On a Honda eu2000 generator. Generator will start then shuts off because overload light comes on

check outlets and wiring for corrosion or short
12/31/2022 1:20:49 PM • Honda Electrical... • Answered on Dec 31, 2022
0helpful
1answer

Honda EX5500 power output

It sounds like you are experiencing an issue with your ex5500 generator where the voltage and frequency are not within the correct range when the generator is running. Here are a few steps you can try to troubleshoot the issue:
  1. Check the load: Make sure that the load you are running on the generator is within its capacity. If the load is too high, it can cause the generator to run at a lower frequency and higher voltage.
  2. Check the fuel level: Make sure the fuel tank is full and that the fuel is fresh. If the fuel is stale or contaminated, it can cause the generator to run poorly.
  3. Check the spark plug: The spark plug is responsible for igniting the fuel in the engine. If the spark plug is dirty or worn out, it can cause the generator to run poorly. Clean or replace the spark plug as needed.
  4. Check the air filter: The air filter is responsible for cleaning the air that is drawn into the engine. If the air filter is dirty or clogged, it can restrict the flow of air to the engine and cause it to run poorly. Clean or replace the air filter as needed.
If none of these steps help resolve the issue, it may be necessary to have the generator checked by a professional. They can diagnose and repair any underlying issues that may be causing the generator to run poorly.
12/31/2022 10:09:19 AM • Honda Electrical... • Answered on Dec 31, 2022
0helpful
1answer

Auger clutch lever disengages even though drive clutch lever is squeezed

On mine (Honda HS55) it turned out to be gummy old grease on the shaft and the lever that are supposed to lock the auger lever down. The spring couldn't overpower the sticky old grease. If nudged or given enough time, it would slowly turn and lock, but not instantaneously, as it should. 10 mm wrench to remove the nut (bottom left) and bolt (under handle) holding on the metal cover. Once cover was off I could see the locking lever, spring, and the shaft that had the gummy grease on it. The third photo shows the locking lever as it should be engaged. I had to push it to engage it, due to the spring not being strong enough for the gummy grease on the shaft. There are flat sides on the shaft, behind the threads for the nut that has already been removed. Use a wrench on those to turn the shaft out. Disassemble. Clean. Oil. Reassemble. Works great now. Another possibility is that your locking lever or spring are broken. 1_zps7a4241d0.jpg 2_zps266fe5e3.jpg 5_zpsb996522b.jpg 6_zps6ca7f90a.jpg
12/25/2022 9:23:21 PM • Honda Snowblower... • Answered on Dec 25, 2022
0helpful
3answers

Honda EU3000is Generator is running poorly.

Can anyone help me with the eco-trottle switch when I switch it on it seems to run the same idle whether I have it off or on, what could be causing it not to work, is it a bad switch or I am running 89 octane could that be the problem.

Thanks
Alex
12/16/2022 4:36:38 AM • Honda 6370C -... • Answered on Dec 16, 2022
0helpful
1answer

I've a Honda eu3000is generator, new carb, new starter. It will electric crank but not start but I can pull start it.

it seems like your ignition switch may not be removing the ground while in the starting position try removing the ground wire from key switch if it turns over and start with key replace switch assy.
12/16/2022 4:25:15 AM • Honda Electrical... • Answered on Dec 16, 2022
0helpful
1answer

My honda 2000 whisperer generator runs then shuts off after about 3 minutes. What could possibly be wrong?

Always use ONLY fresh fuel... (page 32 of owners manual) it is very easy to forget about because HONDA is such an awesome machine... but EVEN MORE LIKELY... HONDA has a very sensitive self protection device Your oil pressure cut off switch could be responding to the WRONG OIL... DIRTY OIL... LOW OIL or WORSE... OVERFILLED Oil. Check it out in your owners manual. ((below) http://cdn.powerequipment.honda.com/pe/pdf/manuals/31Z07610.pdf Honda Generators Generator Operation Honda Power Equipment Owners Manuals http://powerequipment.honda.com/generators/generator-operation#fuel Honda Generators Generator Operation http://cdn.powerequipment.honda.com/pe/pdf/manuals/31Z07610.pdf
11/7/2022 12:00:36 AM • Honda Electrical... • Answered on Nov 07, 2022
0helpful
1answer

Honda em5000sx generator runs too fast

it's possible that u may have a worn washer underneath the governor gear it's internal this washer wears due to lack of oil change 4800 is way too high for that engine to operate 38oo max parts are inexpensive although doing the job to repair it is another it's behind the front cover of engine you need washer slider and governor gear totl cost of parts under 30.00.
11/6/2022 11:47:44 PM • Honda Electrical... • Answered on Nov 06, 2022
0helpful
2answers

Why won't my portable generator start?

Hi, if it was a copy-cat item, it might have been built with cheap parts. Please purchase the real item and you should not have these problems. I would also advise against trying to change a generator's parts because if you mess up, you could accidentally spray carbon-monoxide into your environment which can be deadly. Thank you.
10/12/2022 1:22:15 PM • Honda Electrical... • Answered on Oct 12, 2022
0helpful
1answer

Code 08 in generator honda EM7000 IS What does mean?

Go to this site and down load a manual.
9/29/2022 9:43:55 PM • Honda Electrical... • Answered on Sep 29, 2022
0helpful
1answer

Honda EG1400X generator produces power but after a short time smoke comes out of generator, seems like rotor is overheating. Is this an AVR problem?

There is a short circuit in your stator or rotor coils wires, coil wire insulation broken down, Try to get the stator or rotor rewired or replaced.
8/6/2022 7:09:43 AM • Honda Electrical... • Answered on Aug 06, 2022
0helpful
1answer

Honda SUA 2300 generator surges at idle.

It probably has bad fuel that is a few years old. Check out the videos in the link. What causes a generator to surge at idle? Surging caused by fuel problems usually happens for one of three reasons: incorrect fuel, low fuel levels, or poor fuel quality. Most generators have specific fuel requirements and using any type of fuel outside of those parameters can cause operational issues, including surges. https://www.google.com/search?q=Honda+SUA+2300+generator+surges+at+idle ..
4/28/2022 4:30:53 PM • Honda Electrical... • Answered on Apr 28, 2022
0helpful
7answers

Honda EU3000is generator will not start with electric starter.

I'd say your battery in the generator is going bad or bad. They are very small and do not hold a charge for very long. The noise you heard was probably the starter shaft hitting the flywheel cogs. I doubt any harm was done as long as you did not repeatedly try to start it with the key. Why Honda put a battery in these is because they are intended for use in a campground setting, where they would be used on a daily basis and the battery would constantly charged. Whereas people like us buy them for emergencies only, they sit for long periods, and the battery goes flat, and the fuel clogs the carb and we get the surging issue. That's my 2 cents. When I brought mine home new, I Sta-bil'd the heck out of the gasoline, this past winter, on start-up, the unit surges. Of course the battery was flat.
2/22/2022 3:41:23 AM • Honda 6370C -... • Answered on Feb 22, 2022
Not finding what you are looking for?
Honda Logo

839 questions posted

Ask a Question

Usually answered in minutes!

Top Honda Electrical Supplies Experts

vince

Level 3 Expert

2530 Answers

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Honda Electrical Supply Expert? Answer questions, earn points and help others

Answer questions