1 Answer

...em keb inverter , the E.Pu E.Pu means there is a problem with the power stage. Perhaps your cooling fans are clogged and not spinning. Hard to say with out knowing what the part# of the inverter

Ad

Question about KEB COMBIVERT F5

2 Answers

keb inverter f5 error e.pu General power stage failure. Most likely will need to replace the power stage or inverter. F5 e-pu error could be caused by blocked cooling fan, cleaning/replacement should ...

Ad

...KEB combivert F5 28kva running but after 3-5 minutes have a display error E.OH means over heating blower fan is working condition,pls what the solution of this problem...tnx...... Verify that the ...

Question about KEB COMBIVERT F5

1 Answer

...help troubleshoot better. Maybe a problem with cooling fan if it is an older inverter. Typically when the error E.PU appears, it is too late. Power stage maybe damaged and would need to be

...keb f5 inverter. the part no. is 09.f5.a1d-3a4a, ver. 1.0, 1.5kw. when powering up the drive, it gives 560VDC. please recommend what the problem could be. The E.pu error is a general power stage ...