Posted on May 14, 2011

Our Under-counter Viking Beverage Center (VUAR 141) is not displaying anything on the electronic key pad inside of the refrigerator. It used to display the temperature. Additionally, the light on the inside of the refrigerator is off also. The compressor appears to be running without any problems.

1 Answer

John Frehse

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 1 Answer
  • Posted on Apr 17, 2018
John Frehse
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: Apr 17, 2018
Answers
1
Questions
0
Helped
1649
Points
2

I have a viking beverage center (under counter). Everything froze. How do I know what part will fit my unit and is it called the electronic cold control system??

3 Related Answers

Anonymous

  • 13 Answers
  • Posted on Jun 01, 2010

SOURCE: Viking Wine Cellar Temperature Near-Freezing

Viking wine coolers are made by Marvel.They all had issues with freezing the contents. If you replace the electronic cold control system it will be fine.If you don't, it will freeze the wine popping the corks and leaking in the unit.If you get the parts from Marvell they are much cheaper.

Ad

Anonymous

  • 1 Answer
  • Posted on Sep 28, 2008

SOURCE: Viking all refrigerator

I just started having the same problem with my 48" frig/ freezer Viking Designer series 2 years old- this has been a hot summer, we were not home much and the AC in the house was set higher 78 degrees so the frig I guess had to work a bit more - when I open the door to the frig water droplets acually run down the interior of the door and the box insde is always damp - I also have stress cracks in the interior shell of the frig - repairman is trying to get Viking to fix it- it has been a year now and it still is not fixed- the stress cracks were caused by improper insulation application to the inside of the frig according to the repair people- Also my handles have pealed - like the stainless steel is not really stainless steel - Any ways could the temp in the house changed - does not mean the frig should not work well - For what it costs, I expected better

Anonymous

  • 101 Answers
  • Posted on Mar 25, 2010

SOURCE: 2006 Viking VUAR 141 bar fridge not cooling enough

The thermistor is looking for a very cold temperature before shuting off for the cycle defrost to work correctly. Thus if if shuts off early I would suspect the thermistor or the potentiometer. The pot is connected to terminals # 6 and 7 and should have a resistance over 90K-ohms when set to the coldest position. The thermsitor should have a resistance of 5.6K-ohms at 0 C and near 2.2 at 20 C. The control rarley fails but if it has been recently replaced the DIP switches (there are four of them) may be in the wrong position. If they are in question, try talking to technical customer service at Marvel (they made the unit). Their number is 800-223-3900. Your Viking VUAR 141 should be the same as their 60AR. The thermsitor is usually the most troublesome component but usually fails in the opposite way causing the unit to run too cold.

PS does the cooling fan shut off the same time as the compressor? if not, then the compressor overload is the issue...the the temperature control. If both shut off and on at the same time then you are on the right track.

Good Luck - Subdriver

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
2answers

What are the power switches for on a Danby Beverage Center Model DBC514BLS-1

The power switches for a Danby Beverage Center Model DBC514BLS-1 are the power on/off switch and the temperature control switch. The power on/off switch turns the unit on or off and the temperature control switch allows you to adjust the temperature of the beverage center.
0helpful
1answer

Door seal for a viking beverage center/wine cooler VUWC140

What did you need to know? If it fell out it just pushes back in. Press it in with your thumbs. If you want to replace it its very easy to change. Just pull out the old one and put the new one against the door and push it back into the tracks.
0helpful
1answer

My 1011 year old Viking undercounter beverage center just stopped running. Lights works, door switch appears to work, its getting power just won't start at all.

Hi,

Look into the cold control for your model, you will find that this could have failed and cause this issue you have. Good Luck

I’m happy to help further over the phone at https://www.6ya.com/expert/gere_bf68e6055dd61249

0helpful
1answer

My viking under counter refrigerator freezes all liquid

Is it a digital temp. display? Does this show a low temp? It should show +/-34 degrees. Listen if the compressor runs continuously. It should run for a while and then switch off. When you change the temp setting, as you turn it down, the compressor should stop. If it runs continuously then the likely cause is a stuck/faulty thermostat.Before replacing this, switch off and leave open until unit is at room temp. Then switch on again and monitor. If the thermostat if faulty and the compressor runs continuously you can damage it by overheating. The compressor will run for a good few hours after restart, until set temp. is reached and then switch off automatically. Good luck!
0helpful
1answer

Ge monogram side by side refrigerator ice maker flap not closing and developed ice use hair blower to remove but still keeps happening

Take the ice out look at the flap from the inside...hopefully an easy fix may have to order a new flap moisture gets in there again to vfreeze after you use the blow dryer
0helpful
1answer

I purchased a 52 bottle kitchen aid wine cooler. No matter where I set the thermostat, it is always 45 degrees and readouts are sideways "T's" instead of numbers.

You will need Adobe Acrobat Reader to view these documents. The Adobe Acrobat Reader is available as a free download. arrow_results_summary.gif Get Adobe Acrobat Reader Click Here=> KUWA244PBS Parts List
and here=> KUWA244PBS User and Care Guide
If you should need the service manual you will need to cant me here=> HERE Reason is Whirlpool does not allow me to publish the SM here.

The beverage center and wine cellars have a temperature display for each zone. 12 volts

AC is supplied to the display board from a transformer in the unit compartment. The displays are only temperature displays and have nothing to do with any cooling function. A thermistor is used to sense temperature for each zone. The thermistor for the bottom zone is located inside the lower portion of the separator. The thermistor for the top zone on the wine cellar, (mid zone on beverage

center), is located in the upper portion of the separator. The thermistor for the beverage center upper zone is located on the inside of the 2-piece evaporator cover. It is on the right-hand side.

The mid temperature for the bottom zones on either unit are 60? Fahrenheit plus or minus 5 degrees. The mid temperature for the mid zone on the beverage center and the top zone

on the wine cellar is 45? Fahrenheit plus or minus 5 degrees. The mid temperature for the

top zone on the beverage center is 38? Fahrenheit plus or minus 5 degrees. I think at tis time you should check each section with a pocket size digital thermometer to cofirm tha the mechanical thermostat is within calibration. Click Here=> 4344690 Temperature Control


sea_breeze_250.jpg

Click here for a=> KUWA244PBS Beverage Center Wiring Diagram
I believe the problem may be in the PCB transformer shown at the bottom right corner of the wiring diagram. It is possible o change the transformer but I have not been able to find the board that powers the LED temperature readouts. If needed let me know and I will call Whirlpool mfor you, Thanks, Sea Breeze

1helpful
1answer

2006 Viking VUAR 141 bar fridge not cooling enough

The thermistor is looking for a very cold temperature before shuting off for the cycle defrost to work correctly. Thus if if shuts off early I would suspect the thermistor or the potentiometer. The pot is connected to terminals # 6 and 7 and should have a resistance over 90K-ohms when set to the coldest position. The thermsitor should have a resistance of 5.6K-ohms at 0 C and near 2.2 at 20 C. The control rarley fails but if it has been recently replaced the DIP switches (there are four of them) may be in the wrong position. If they are in question, try talking to technical customer service at Marvel (they made the unit). Their number is 800-223-3900. Your Viking VUAR 141 should be the same as their 60AR. The thermsitor is usually the most troublesome component but usually fails in the opposite way causing the unit to run too cold.

PS does the cooling fan shut off the same time as the compressor? if not, then the compressor overload is the issue...the the temperature control. If both shut off and on at the same time then you are on the right track.

Good Luck - Subdriver
0helpful
1answer

Under counter beverage air refrifgerator stop

It needs to fill the the circuit of the refrigerator motor with gas.
0helpful
1answer

Beverage air mt 17

their web site says it is to maximize defogging.
http://www.beverage-air.com/images/glassDoorMerchandisers/manuals/809-005A.pdf
See if you can get to their web site. In the operations section, under initial start up, it talks about this. Can't find anything else on this.
Good Luck-Hope this helps.
0helpful
1answer

Under counter beverage cooler

It might be ice around the fan. Try defrosting it. This has been happening to mine, even through it is supposed to be 'frost free'
Not finding what you are looking for?

1,659 views

Ask a Question

Usually answered in minutes!

Top Viking Refrigerators Experts

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

Are you a Viking Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...