You got few :
but 1st turn the main power off!!
open the 2 screws on the panel between the washer door to the main control panel(its diagonal panel)
in front of you there is a bid metal plate with few screws - open them all to get that panel out.
now you see few of your fuses on the pip of the air duct (on the bottom)
now the other fuses are on the heating element which is behind the main drum.
you can try to reach them by taking the roof out but if you cant you need to:
take the control panel out (4 screws , 2 each side (1 silver 1 small black))
take the door panel out (4 screw on top 2 screw bottom each side)
disconnect the door switch wire
now you can disconnect the belt and lift the drum and pull it out (2 man job)
you can see now the heating element and all other parts.
you can check which fuse burn and clean the whole machine from lint.
put it all back the way you took it and it the door panel heard to put(heavy) disconnect the door(4 screws on hinges) it will be light to pick it up now. :) good luck
Hello Mike Brady - From what you have described it seems like the dryer is experiencing a wiring failure or a communication error with the control board. Contact a professional to move forward accurately.
204 views
Usually answered in minutes!
×