Electric dryer no start does nothing
Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.
CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.
NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.
If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is onONposition. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings
Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt.The belt safety switch is attached to theTensionerand motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under theTensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.
Lastly checkurDOOR SWITCH ?for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.
https://www.youtube.com/watch?v=MhVUEhngZMg
https://www.youtube.com/watch?v=9xD7lCXJ0ZM
https://www.youtube.com/watch?v=sTRP6kHqAFs
Hey GOD IS GOOD !!!! WHICH IS WHY MY ADVICE IS FREE
SOURCE: whirlpool duet ht wouldn't start
remove the lower front panel,3 screws,side up and off,there is a tech sheet inside on the panel that should help you ,let me know what you find-mike
SOURCE: Whirlpool Duet Dryer is scorching clothes
there is a sensor in the exhaust line in the dryer, near the motor. this tells the heating element to shut off when it gets to a certain temp, either during reg cycle or if the exhaust gets clogged, it is meant as a safety measure, but it sounds like yours is bad so the heating element never shuts off. it is not an expensive part and easy to replace
SOURCE: Whirlpool Duet Dryer WED9600 Beeping during drying
Dear Customer
Please perform the following
please rate this,thank u
SOURCE: Whirlpool Duet Steam Dryer Beeping
Symptom: Dryer turns on, drum spins, but you have no heat.
Any of the following components are more than likely suspect as being bad:
Heating Element
Thermal Cut-Out
Hi-Limit Thermostat
All these components COMBINED, should cost less than $100. If you fix it yourself, you will avoid the additional cost for labor.
If the dryer isn't blowing ANY air at all, but the drum still turns, you may have a bad blower fan assembly inside the dryer. Or, the blower fan assembly may be clogged.
If your dryer performance has been failing (i.e., clothes taking longer to dry), it may be for a reason. You need to ask yourself when the last time you cleaned the dryer ventilation. If you can't remember, or if it has never been done, this can contribute to the dryer failing. All dryers need proper air flow in order to dry properly. If the ducting becomes clogged, the heating circuits will actually overheat and eventually fail. This usually results in the Thermal Cut-Out (TCO) blowing or the Heating Element failing or BOTH. When these components fail, they must be replaced. Remove the dryer hose from the back of the dryer and inspect it thoroughly from where it leaves the dryer to where it exits your home. It should be clear with no kinks or clogs. If your vent line runs under a crawl space make sure it is suspended above the ground and has no sags where lint could collect. RULE OF THUMB: The SHORTER and STRAIGHTER the vent duct, the BETTER. After you inspect the vent ducting, turn the dryer on and make sure you have forceful air flow coming form the dryer. This will prove that your blower fan is working properly or not. Since you stated that your dryer is not currently heating, the air will be cold, but you should still have some force behind it. If the air flow is weak, you need to clean the duct work INSIDE the dryer. It is important to keep a dryer checked routinely. I recommend once per season (that's 4 times per year). Dryers are the cause of many house fires. These fires are due to lint accumulations inside the unit catching on fire. A little preventive maintenance can prevent significant problems in the future.
Getting to the heating circuit to determine if the components are good or bad is the next step. If your dryer has the lint screen on the top of the unit, you will need to remove the back panel of the dryer to expose the heating circuits. If the dryer has the lint screen in the door, you will need to remove the lower kick panel under the door by using a putty knife to release the retaining clips. They will be located along the seam in the front about 2 inches in from each side. If this is a Kenmore Elite or Whirlpool Duet, the lower lick panel comes off by removing the screws under the bottom edge of the panel. (HINT: placing a block of wood under the front feet of the dryer can make access much easier). If your dryer has no lower kick panel, you have to remove the entire front panel on these models. This is accomplished by lifting the dryer top and removing the screws that hold the front panel in place.
NOTE: The heating circuit should be troubleshot with the dryer UNPLUGGED. Dangerous voltages are still present with the dryer turned off. Resistance readings are as follows:
Heating Element (located inside heater box) - remove the two leads from the ceramic terminals on the heating element and take a reading across the terminal points. It should read 9 - 13 ohms.
Thermal Cut-Out (TCO) (mounted to the heater box.) - unplug wires and take reading across connector tabs. Reading should be 0 ohms.
Hi-Limit Thermostat (mounted to the heater box, closest to the heating element leads) - unplug wires and take reading across connector tabs. Reading should be 0 ohms.
If any of the above readings are abnormal, replace the component. NOTE: If the TCO or Hi-Limit Thermostat is defective it is highly recommended by most manufacturers to replace BOTH components at the same time. They are often sold as a set. Without doing so, these components can cause potentially fail again.
NOTE: One item I failed to mention - Double check the input power for your dryer FIRST. You should have 220VAC at the receptacle and terminal block. The dryer will STILL tumble and the timer will still function with a portion of the input power missing as these circuits only require 110VAC. The heating circuits, however, require 220VAC to function. If one leg of the receptacle voltage is missing the dryer may exhibit "No Heat" like symptoms. This could also be an indication of a burned or failed power cord. Continuity checks performed with the dryer UNPLUGGED should indicate a short between the prong end of the cord and the respective lugs at the terminal block.