FREEZER /FRIDGE NOT COOLING: Optimum refrigerator temperature at or below40° F(4° C). The freezer temperature should be0° F(-18° C). Check temperatures periodically. Appliance thermometers are the best way of knowing these
Check ur cold control thermostat, ur thermistors in both fridge and freezer ( they should be checked for both ohms and for amount of current being put out as per ur model ), ur air flow vent from freezer to fridge.( to make sure it opens and closes without any restrictions) On thermistors check for A close circuit and amount of ohms not just an Ohm reading. As per ur model. Most should atleast show 1200 ohms. Also Check door seals for leakage.
Evaporator coils
Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets.
If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited.
FAN check to see if it is operating or restricted A fan that is not blowing or restricted will not circulate the cold air properly.
Often, the first thing that folks do when their refrigerator starts to feel warm is turn both controls on the coldest settings.This is exactly the WRONG thing to do.Turning the cold control to the coldest settingwillkeep the compressor running longer and make lots of cold air.
But turning the air door to the coldest settingclosesthe airway to the food section. Lots of cold air is made, but most of it stays in the freezer section, and the food section actually getswarmer.
Condenser
Self-defrosting refrigerators all have a set of coils and a cooling fan, usually under the refrigerator, that need to be cleaned regularly. If these coils get coated with dust, dirt or lint, the refrigerator may not cool properly. The coils may appear to be a thin, black, wide radiator-like device behind the lower kick-panel. To clean them, disconnect the refrigerator from the power source, use a refrigerator condenser brush and your vacuum cleaner to clean the coils of any lint, pet hair, etc. You may not be able to get to all of the condenser from the front, it may be necessary to clean the remainder of the condenser from the rear of the refrigerator.
May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..
THE COMPRESSOR:
If you hear a clicking sound coming from the back of your refrigerator/freezer, then the problem is most likely the compressor, relay and or capacitor is overheating or not getting proper power and will not start.The compressor is the component on your refrigerator that allows your refrigerator to cool. If this component is not working properly your refrigerator will stop cooling. Most of the time the compressor is not the component that has failed.
To check ur compressor with multi meter:
Disconnect and remove the relay and capacitor from compressor, some located next to compressor in a casing.
You wills see 3 prongs coming out of compressor. 1 goes to ur start winding, 1 goes to ur run winding and the center goes to ur ground.
Place ur meter connector or prong on the start prong and the other on the ground (center prong) take note of the reading in OHMS for example 5 ohms.
Next place meter prong on run prong and the center ground prong agin. Take note of the reading in OHMS. Example 4 ohms
Next place meter prong on the start prong and the other on the run prong, now take note of the reading example 9 ohms. Now match the total of this ohms test with the total of ur two separate test. 9 ohms, if they match ur ok give or take 5 percent plus or minus. One more test to make to test of there is a short in compressor attach meter prong to ground prong and rub the other end of meter prong to metal ( scrape the metal clean of paint and test on metal surface not painted surface. If it shows continuity or ohms , u have a short in ur compressor. It should show infinity
TO REPLACE RELAY AND CAPACITOR WITH A HARDSTART KIT YOU CAN USE
A 3 in 1 start kit for compressors sizes 1/4 through 1/3 HP. And a 5 in 1 for higher H.P. (BE SURE TO MATCH WITH UR COMPRESSOR MODEL NUMBER AND TYPE) The kit includes relay, capacitor, and overload device, pre-wired. The kit will replace all 3 electrical components on capillary refrigeration systems. For newer systems with a run capacitor use proper kit. For smaller horsepower compressors useTJ90RCO810.
The wire set up is as follows the red wire goes to the right side of compressor prong, the white wire to the left side prong, the black wire to the center prong, and the 2 other black wires go to the power and the ground connection
Lastly you should also check ur THERMISTORS in the freezer and fridge section for continuity OHMS and for amount of OHMS current being put out. In most models around 13000 ( give or take 150 ohms) ohms is required.
1-3 TEMPERATURE CONTROL
As the food in the fridge gets colder, it gives off less heat, and the air inside the fridge will remain colder. A thermostat called aCOLD CONTROLwill cycle the cooling system on and off to keep the temperature inside your fridge within a certain range. You can adjust that range using one of the dials within your fridge.
On most fridges, all the cold air for both the food compartment and the freezer compartment is produced in one evaporator. Since the freezer is so much colder than the food compartment, most of the cold air that is produced circulates to the freezer compartment. Only a small amount is needed in the food compartment to keep it down to the proper temperature. This amount is adjusted by a smallAIR DOORin the duct between the evaporator and the food compartment. The control for this air door is the other of the two dials within your fridge.
If you hear your compressor "short-cycling" (starting and stopping at short intervals) try jumping across the two leads of the cold control thermostat ( in the fridge compartment) with an alligator jumper. You can also check both for live voltage current and ohms- If there is a greenthirdlead, ignore it for this test; it is the ground wire. If the fridge starts running constantly, the cold control is bad. Replace it.
To test or change the cold control, first Pull the knob off it and remove any plastic cover plate or housing from it.
You will see two wires leading to it. There will also be a thick, stiffCAPILLARY TUBEattached. The capillary tube is the liquid-filled temperature-sensing element of the cold control, and operates in the same manner as a thermometer
The air damper, baffle or diffuser is the device that balances the air flow from the evaporator fan housing. This normally is a mechanically controlled baffle or flapper that controls the amount of cold air entering the fresh food compartment. If the baffle is damaged or the linkage to the control knob is damaged, then you may not have enough cold air entering the fresh food compartment resulting in higher than normal temperatures. This baffle or damper will be located where the cold air enters the fresh food compartment.
Read more:
http://removeandreplace.com/2013/10/31/fix-refrigerator-freezer-wont-cool-freeze/#ixzz3WDEo5NDJ
http://www.appliancerepair.net/refrigerator-repair-1.html
https://www.youtube.com/watch?v=KqXN-ZCuptk THIRMISTOR CHECK
https://www.youtube.com/watch?v=53ZFeiWgtuk
https://www.youtube.com/watch?v=-L80Fk5had4 defrost timer
REMEMBER GOD IS THE REASON FOR GOOD ADVICE"
SOURCE: Amana French Door Refrigerator "on" but no cooling; freezer still works
There are 2 possible problems. One is the defrost cycle is not working properly this is usually indicated by a large amount of frost on the back freezer panel. If so, the circuit will have to be repaired and the evaperator thawed to remove the ice build up. The other is the fresh food damper is not working properly this is behind the "lump" in the back of the fridge compartment above the top shelf, remove the louver panel to see if it is open or closed. closed will be warm open should be cold. The water dispenser reservoir is probably frozen due to poor air circulation.
SOURCE: GE Profile French Door Bottom Freezer not cooling
I am experiencing the same problem with my GE fridge. We have already tried the Turbo Cool, but nothing seems to help.
Thanks
Carol
SOURCE: Warm Fridge Section, Cool freezer section
Problem seems to be solved. I unplugged it for a short time and plugged it back in. I'm guessing it needed to be re-set.
SOURCE: maytag french door frig - Freezer works, frig warm
sounds like the freezer fan motor is worn out
SOURCE: Refrigerator doesn't cool/freeze - clicking, cyclying noise repeates, but doesn't cool
I've been told by a tech who repaired my MFD2560HEQ this past week that many of this model had a problem with compressor failure. Your symptoms are classic. What you are hearing is the starter relay trying to start a warm/hot compressor by supplying it with an extra jolt of electricity, but because of the faulty compressor (or if you are lucky a faulty relay) that's warm (cool ones start more easily often) is refusing to budge into motion and compress the freon. Maytag, I believe, has a five year warranty on the compressors. They did on mine, but unless you have an extended warranty the labor replacing it is not covered and that will be around 2-3 hours worth. This is the price we are paying for our quest for energy efficiency. Compressors are being built so small and light that they fail much more often than grandma's old, old refrigerator that was built like Fort Knox and ran for 45 years, remember? But we're being energy efficient! Thank you environmental extremists! I wish I could send you the repair bill.
Hi,
Check out these tips...they can help you figure out what is going wrong with your refrigerator and why it is not cooling
Refrigerator not Cooling or Fridge not Cooling
How to Defrost Refrigerator Defrost Timer Problem
Water Running in refrigerator from Freezer
Refrigerator or Freezer not Cooling or Getting Cold
heatman101
Hi,
Check out these tips...they can help you figure out what is going wrong with your refrigerator and why it is not cooling
Refrigerator not Cooling or Fridge not Cooling
How to Defrost Refrigerator Defrost Timer Problem
Water Running in refrigerator from Freezer
Refrigerator or Freezer not Cooling or Getting Cold
heatman101
162 views
Usually answered in minutes!
×