SOURCE: 50K BTU Reddy Heater Trips Circuit Breaker
If the unit lights Check the photo cell this can be done with an ohm meter and good light. Should have continuity in light.
SOURCE: burning eyes and sore throat when heater is on
This heater should only be used in a very well ventilated area, the sore throat and burning eyes are from carbon monoxide.
Carbon monoxide is potentially fatal.
I cannot express how dangerous this is if used in a house or garage without the doors open
Please be careful and let me know if I can provide furthur assistance.
Lone99star
Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/jason_77a19afa8d604dee
SOURCE: Reddy Heater Kerosene 50,000 BTU produces TOO
There are2- adjustment screws on the back 1--air---#2-fuel. adjust it while running for the perfect combination for the fuel/ air ratio.!
SOURCE: 150,000 BTU propane Reddy Heater shuts off after ignition
Is there a frost line on your LP tank, if so you may need to replace the tank with a larger tank or refill your tank. This can happen if the tank your using is too low or too small (use 100 lb tank or greater). If there is no frost line it may be an issue with the thermocouple. The manufacturer offers a service manual and owner's manuals on there site. This should assist you... www.desatech.com Thank you