Suddenly my BurCam 3/4 HP pump keeps turning on and off. I’ve closed all values to sinks and stools and laundry and it continues. What should I do next?

1 Answer

Steve Pack

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Washing Mach... Master 7,128 Answers
  • Posted on Jul 25, 2019
Steve Pack
Washing Mach... Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Oct 15, 2013
Answers
7128
Questions
1
Helped
2275594
Points
27972

Check or replace pressure switch, check suction check valve. If valve leaks mater will drain back. Replace pump.

2 Related Answers

Anonymous

  • 407 Answers
  • Posted on May 22, 2009

SOURCE: regarding the value to be know

Yes, you would do a LOOKUP do display the row number.

LOOKUP(H53,A1:G1000,0)

Ad

Anonymous

  • 179 Answers
  • Posted on Jul 12, 2011

SOURCE: My 3 month old washer

The washer is detecting too much soap. Make sure that you are using HE (high efficiency) soap Do a clean washer or hot cycle once a month with bleach or white vinegar with no clothes in it. Your washer only uses half the water that a regular machine does. The HE is specially designed for front loaders and these types of machines

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Burcam tankless jet pump wont turn on all lights are on

What is your model number on this, also you can contact directly at T 514.337.4415
0helpful
1answer

What is the value of my vintage cable upright piano serial number 307307 in excellent condition

If you have one with the matching stool, it could be valued at $29.800. Without the stool it is worth about $300.
May 15, 2014 • Music
0helpful
1answer

Dryer will stay on when started

Don't do GE products if you have a push to start then I would suspect the centrifugal switch in the motor this is what keeps a closed electrical loop for the motor
Mar 22, 2014 • GE Dryers
0helpful
1answer

I have the 1/3 hp, 115v model. My pump is in my basement and below my utility sink, it pumps overhead then out to the road. It will pump water out, but then will try to keep pumping. Not continuously...

Do you have a check valve on the discharge line going to the street? This would prevent the backup of water back to the pump making it want to come back on. Things you can try, can you make the holding tank under the sink larger so more water need to be present before it comes on? Also have you tried to put a vacuum break on the system? You can make one easy by razing the outdoor discharge pipe two to three feet high just as it comes out of the house, place a upside down "U" at the top that flows into an open larger pipe that take it to the street. This way if you are getting a back flow you will only get the amount of water between the pump and the upside down "U", however if it was me I would be sure there is a check valve close to the pump so a back flow cannot happen, you can get them at your local hardware or pluming store.
Lastly, the float is adjustable in two locations, one is the location of the float when the maximum water level is reached (turns on the pump) and at the level of water where it turns off the pump, giving a buffer area so if there is flow back it takes more to turn the pump on and less to turn it off, try playing with these two levels on the float.
0helpful
1answer

Burcam 300521 Instant Hot Water Genie 115v

Check: http://www.h2oplus.us/id97.html

Wal-Mart, Sears and others have the pump and can get the by-pass valve. As far as your problem You forgot to tell us!
0helpful
1answer

Mastercraft 62-3593-2 jet pump

That pump doesn't have a pressure switch! It has a digital flow sensor on discharge. It will keep running so long as there is a flow. Usually caused by dripping tap, or leak. Pressure doesn't stop the pump. By the way - Don't expect to get parts from Canadian Tire or Mastercraft - They told me that they carry NO parts for that pump. It is very similar to a Burcam pump and they may have parts or offer service.
Jun 02, 2013 • Plumbing
0helpful
1answer

My sanivite 3 has a washer connected to the bottom inlet and a sink to the top inlet. when water is run from the sink the system will pump the water out, however when the washer is discharging waste the...

A washing machine discharges water water at a very high velocity and high capacity. This is far more waste water than the pump was designed to handle. The washer discharge must be connected to what's called an "indirect waste", that is, it must discharge into a laundry tub or sump, so that the excess can be stored until it can be taken by the pump. The specific code that governs this is in chapter 27 of the International Residential Code.

Also in the manufacturers instructions, they allow the discharge from a washing machine ,through an indirect waste. [sic] "The Sanivite is a drain pump that is ideally suitable for use in a basement apartment or anywhere in the house where additional fixtures are most wanted. It will pump waste water away from a variety of sources such as: a kitchen sink, laundry sink, washing machine ***(indirect connection)***, dishwasher, bar sink, etc."

This pump will never be able to handle the discharge directly and you need to provide a receptor to accommodate a washing machine. Is there any possibility of adding a laundry tub adjacent the washer and Sanivite pump?
0helpful
1answer

Frigidaire Laundry Center won't pump out water

The resistance of any mechanical switch is, practically speaking, 0.0 ohms.

If you are checking continuity across the two terminals of the lid switch, just use the continuity setting on the multimeter. If you get the audible signal with the switch closed the switch is good.

But, the lid switch has nothing to do with the drain function. The lid switch just keeps the tub from spinning with the lid up -- (given the picture at the top of your post is the machine in question).

If the mcahine won't pump but otherwise operates normally, first, I would suspect the pump could be malfunctioning.

Charlie
4helpful
2answers
Not finding what you are looking for?

135 views

Ask a Question

Usually answered in minutes!

Top Washing Machines Experts

Brad Brown

Level 3 Expert

19187 Answers

Cindy Wells

Level 3 Expert

6688 Answers

john h

Level 3 Expert

29494 Answers

Are you a Washing Machine Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...