Question about Denon Audio Players & Recorders

1 Answer

I have denon AVR 3310 but when I turn on some seconds it turns. The red indicator blinks, what might be the problem?

Posted by Anonymous on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Loyalty:

    Visited the website for 30 consecutive days.

  • Expert
  • 130 Answers

(1)Download AVR3310 service manual.
(2)enter debug mode to see what kind of protect it belongs to.
(3)DC or ASO protect
(4)DC protect to check all smd transistors if leakage occurs or
differential and voltage amp transistors leakage
(5)ASO see service nanual troubleshooting steps.
(6)Replace all defective components.

Posted on Jun 24, 2019

Ad

6 Suggested Answers

6ya6ya

6ya staff

  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Anonymous

SOURCE: Powers turns on then off

See: http://www.denon.ca/hapdfs/avr2105mane.pdf, page 72. In my case, the problem was a connector between my receiver and television. I unplugged it from my receiver and it now works.

Posted on Jul 08, 2007

Anonymous

  • 624 Answers

SOURCE: Denon AVR-1907 blinking red power button

It sounds like you have a bad speaker on the zone 2, or you have the speakers connected improperly.

When you engage the zone 2 a relay clicks and the speakers then become part of the amplifiers circuit.

If the problem was in the amplifier, it would go into protect mode without even having speakers connected to it.

If the speakers all check good, you most likely have the wrong type of speakers, meaning the impeadance is too low, or you have too many speakers connected to it.

On the back of the Denon, you will see right around the speaker output jacks, what ratings the speakers should be. If I remember correctly, it says 6 ohms or more when using only "A" or "B", and it says 12ohms or more for "A" + "B".

If you have two 8 ohm speakers on the same speaker jack you now have a 4 ohm load. That is below the ratings and can cause the amp to shut down (go into protect). Since your amp shuts down right away, I think you have a bad speaker or way too many speakers connected.

I have seen many times when people will connect 2 or 4 speakers to the one of the outputs that are designed for only 1 speakers.

If you are using too many speakers you will need a speaker distribution box. It has a resistor network built into it so the amp never sees a lower impeadance than what it is designed for.
You can connect 4, 6 or 8 speakers to one set of outputs designed for 2 speakers. You do loose a lot of power to the speakers, but it is better than blowing up your amplifier.

If I can be of any further help, let me know.

Posted on Jun 22, 2008

localwonder

Michael Masters

  • 6784 Answers

SOURCE: shuts off then red light indicator flashes, disconnected all speakers but still wont work

Hi, this is a power board issue. remove the cover and make sure that this unit doesn't have blow fuse. if the fuse is fine, you will then need to replace the integrated power/ main board.

Posted on May 21, 2009

SOURCE: Denon avr-1804 its turns back after 5 sec

Disconnect all speaker wires on back and then turn on. If it happens again, it's most likely a power supply problem. If it doesn't happen again, it was probably crossed speaker wires.

Posted on Dec 28, 2009

EBC ELECTRONICS

  • 163 Answers

SOURCE: red power light blinking on my denon avr 1907,

This is a protection mode. The receiver protection circuit detects an internal problem like missing power supply voltage or blown channel and shuts down the receiver. You need to bring the unit to a repair facility.

Posted on Sep 28, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Denon AVR-1312 turns on displays for a second switches off and the red light starts to flash


you most likely have a shortedchannel in the amp that would need to be repaired

Jul 31, 2014 | Denon AVR1312 51 Channels Receiver

1 Answer

Blinking red light


How many times this power/standby light blinks? It is fault indication, and are fault codes. If you wish to get some details about these codes, try this link. http://electronicshelponline.blogspot.com

Dec 22, 2013 | Denon AVR-1513

1 Answer

When I turn it on it stays on for just a few seconds and it turns off with the red on syanby blinking , what's going on there?


try turning off for 30 seconds and then back on while pushing speaker, A & B Buttons at once. If this doesn't work it could be the capacitors in the power supply.

Jul 30, 2011 | Denon AVR-1802 Receiver

2 Answers

Denon avr-1506 will turn on then flash red and turn off... how do i make it stop or fix it??


In most AV receivers if the standby light flashes after turning on and you don't hear the regular click of the relay engaging after 4 seconds, indicates an output short or amplifier failure. The protection circuit prevents any further damage by not turning on system.
You will need professional help to fix this problem because even to a electronic enthusiast the construction of a typical AVR is not service friendly.

Jul 01, 2011 | Denon AVR-1506 Receiver

1 Answer

I have a Denon AVR 1509 and when I turn the power on it flashed green but after about 2 seconds it cuts out and and then flashed red every 0.5 seconds.


Usually its the power output stage . You can visibly check it if theres a burned resistor on the output amplifier. On the base of the Power output transistor if the voltage is the same as the collector pin it will indicate a shorted power amplifier circuit.



May 20, 2010 | Denon AVR-1508 Receiver

2 Answers

Denon avr -1709 how do i get it reset to factory specs


SWITCH OFF THE UNIT..PUSH AND HOLD DOWN BOTH SPEAKER A AND SPEAKER B BUTTON WHILE HOLDING DOWN BUTTONS TURN ON MAIN POWER THE DISPLAY WILL FLASH WAIT FOR 3 FLASHES THEN RELEASE. THIS WILL RETURN EVERYTHING BACK TO RFACTORY DEFAULT

Mar 21, 2010 | Denon AVR-1708 Receiver

3 Answers

What is the master reset code for the denon avr 1508?


Turn the unit off by main switch (not a standby button).
Press and hold "Speakers-A" and "Speakers-B" buttons and turn on main switch.
Display blinks.
Release the buttons after 3 seconds.
Receiver is reseted.

Jul 20, 2009 | Denon AVR-1508 Receiver

1 Answer

Denon 4308CI power


Tienes un problema con los amplificadores de audio de tu aparato.

Mar 17, 2008 | Denon AVR-4308CI Receiver

2 Answers

Denon avr-886 VERY FRUSTRATED


Read the manual. You've either got crossed speaker wires, it's overheating, or it's a more serious problem. The same just started happening to mine, so I'm taking it in.

Oct 03, 2007 | Denon AVR-886 Receiver

Not finding what you are looking for?
Audio Players & Recorders Logo

Related Topics:

49 people viewed this question

Ask a Question

Usually answered in minutes!

Top Denon Audio Players & Recorders Experts

 Grubhead
Grubhead

Level 3 Expert

5699 Answers

The Knight
The Knight

Level 3 Expert

76186 Answers

Marvin
Marvin

Level 3 Expert

85216 Answers

Are you a Denon Audio Player and Recorder Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...