SOURCE: Amana French Door Refrigerator "on" but no cooling; freezer still works
There are 2 possible problems. One is the defrost cycle is not working properly this is usually indicated by a large amount of frost on the back freezer panel. If so, the circuit will have to be repaired and the evaperator thawed to remove the ice build up. The other is the fresh food damper is not working properly this is behind the "lump" in the back of the fridge compartment above the top shelf, remove the louver panel to see if it is open or closed. closed will be warm open should be cold. The water dispenser reservoir is probably frozen due to poor air circulation.
SOURCE: Refrigerator Compartment Fan
Sounds like they ran it in with your themostate and it is not working.. i would try replaceing themostate
SOURCE: 5 year old Maytag Wide by Side Refrigerator side not cooling
Same issue with my 6 yr old Maytag side-by-side model #MSD2756GEW. Turned out it was caused by a faulty circuit board. This circuit board is located in the upper right fridge section. Apparently these boards are sensitive to power surges (which we have here in central Texas from time to time.) When the circuit board is fried, it makes a noise like a fan blade malfunctioning and it stops the auto defrost feature in the freezer from working. So the freezer ices up at the back, and the ice prevents the cold air from reaching the fridge section.
Our circuit board (which we thought was a fan) made ominous noises for a few months. (The noise would last only a minute or so and stop shortly after we opened a door). Eventually we noticed that the fridge wasn't as cold and the freezer had snow in it. Finally the board stopped making noise and about a week or so afterward we noticed that the milk had spoiled and the fridge wasn't very cold. The food in the freezer side pretty solidly frozen, thankfully.
In addition to replacing the circuit board, the fridge had to be de-iced or it would not work properly. I put it all frozen into a large camping cooler where it stayed for several hours. I opened the freezer doors and put table fan and pointed a hobby light which gets quite hot, at the back of the freezer. Within 3 hours, the ice had melted significantly so I could see through the grate at the back of the freezer. This really great technician named Tracy, made a special trip to the parts store to get the circuit board and came back within a couple hours, bringing with him a steamer. He removed the back panel inside the freezer section (the coils are behind there) and used the steamer to melt the rest of the ice before he left.
Tracey, who works for a local appliance repair company, told me that about 4 years ago, Maytag started making their fridges with built-in surge protection, so the circuit boards apparently don't get fried on the newer models as they do on my 6 yr old model. He recommended that we put plug the fridge into a heavy-duty surge protector - which we are definitely going to do.
TR
SOURCE: Amana BX22A2W - freezer works, fridge not cooling
Check the damper in the top back of the fresh food section. make sure that it is open and air is coming through it.
SOURCE: Amana Cooling Condensing Unit fan stops spinning after 15 mins
Capacitor, dirty condencer coil causing the motor amps to run too high. But most likely worn bearing on blade side of motor causing it to pull to one side causing it to over heat and shut down. Sleve bearings should have no side play.
Sounds like they ran it in with your themostate and it is not working.. i would try replaceing themostate
1,373 views