Check the light switch. Unplug power. remove wires from light switch. Check the light switch.
I would say the light switch is stuck or "welded" contacts. In my ge, the light switch is in the upper part so that the switch moves up into the upper right surface when the upper right part of shelf slides against this switch. The sliding part of the switch may be dirty or perhaps broken off. so the switch stays on all the time. My freezer side has the same switch arrangement. Look at your freezer side to see what the switch looks like and how it is supposed to work. Appliance parts sites usually have parts and instructions for how to replace.