1 Answer

How do I calibrate or gauge after replacing a rotor kit?

Posted by Anonymous on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    New Friend:

    An expert that has 1 follower.

    Corporal:

    An expert that hasĀ over 10 points.

    Welcome Back:

    Visited the website for 2 consecutive days.

  • Contributor
  • 12 Answers

When the rotor has been replaced, you will need to reset the clearance at the top of the rotor and the pump body for the correct operation, details can be found in your manual. Too wide a gap and you will have low pressure, to small a gap and there is the risk of damaging or scoring the new parts. Once the heater is running, adjust the air pressure so that the flame is staying just inside the combustion chamber or just around the edge of the end plate. It should be red hot and burning without any smell or un-burnt fuel. Damage will be caused to the combustion chamber if the flames come out the end like a jet engine, as well as being dangerous. It's not really necessary to use an actual pressure gauge, use the performance as your guide. Pressure gauges are a useful diagnostic tool if repairing heaters is your business, because you can immediately tell if the fault is caused by air pressure or other problems.

Posted on Mar 03, 2015

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a 2004 Ford Explorer sport track, the oil pressure gauge went to zero back 1 month ago, we changed the oil sending unit, no change. Any ideas on what next?


You need to get an actual pressure test on the block to get an actual reading, because I would hate for you to have lubrication problems in the engine and blow the engine. If the gauge is stuck on zero try with the engine off and key on, ground the sending unit wire to the block and see if the gauge pegs to full. If it does not, replace the gauge and get it calibrated if it needs calibrating.

Mar 05, 2016 | 2004 Ford Explorer

1 Answer

1994 Mercury Grand Marquis temp gauge reads hot


Check sending unit, Ford/Mercury put out a TSB, technical service bulletin : Article No. 95-13-2 07/03/95, on erratic temp sender units.
You troubleshoot as follows :
  1. Turn ignition switch to On or ACC position.
  2. Connect a 10 ohm resistor between gauge lead and ground. The centerline of pointer should fall within the band around the H mark.
  3. Connect a 73 ohm resistor between gauge lead and ground. The centerline of pointer should fall within the band around the C mark.
  4. If gauge tests within calibration, replace sender.
  5. If gauge is out of calibration, replace gauge.

Mar 16, 2013 | 2000 Mercury Grand Marquis

1 Answer

Hi. I have a 1990 c1500 silverado. Originally it had a manual gear box which was replaced with a turbo 700R4. Now ive put in a new engine and a turbo400. the T700 came with an electronic pulse generator...


I would use the electris set up for a 400,they were availiable in the late 80s and you can still get the parts.The rotor(tone) is different that 700 because inside hole is larger.You can buy a kit from GM to reprogram the cluster to match tire size and ratio.Calibration Kit - 25085515
Re-Programming Kit - 25084374
F-LENS - Clear Instrument Cluster Cover - 16130044

Feb 14, 2011 | 1990 Chevrolet C1500

1 Answer

Does the fuel gauge need to be calibrated after replacing the fuel pump assembly unit? And which oxygen sensor needs to be replaced when you have a significant drop in MPG and the exhaust smells rich?


Fuel gauge should not need to be calibrated. As for the o2 sensor, it would be the front one more than likely. I would also check to make sure that the Mass Air Flow sensor is not causing the problem before just putting o2 sensors in. Is your check engine light on?

Jan 03, 2011 | 2001 Chevrolet Impala

1 Answer

Outside Temp. Gauge


Can't be calibrated. If you do decide to replace it, just as a warning, the whole curcuit board in there will need to be replaced, and that item is a manufacturer speciality item, so a Ford garage will be the only place you will be able order one from, and it will be expensive.

Mar 13, 2010 | 2005 Ford F-150

2 Answers

I need calibration paper for the DS mobile scanner


Calibration Sheets and Cleaning Kit $2.98 plus shipping.
http://www.opticsplanet.net/pentax-dsmobile-600-calibration-cleaning-kit-206717.html

Jan 22, 2010 | Pentax DSmobile Path-Through Scanner

3 Answers

Small tabs next to inside front rotors rubbing. What are these for? 2005 Chev Equinox


they are called wear indicators time to replace your brakes before they damage the rotors

Sep 27, 2009 | 2005 Chevrolet Equinox

1 Answer

My 2004 gmc envoy stalls when sitting at the light or idling to long


premium gas is a waste of money. domestically produced and sold cars are actually calibrated for econo gas. well, based on what you told me and the type of vehicle, i'd invest in some well-needed maintainence (COMPLETE tune up with AC Delco platinum plugs, fuel filter, air filter, pcv, cap and rotor) don't skimp on cap quality either- told ya -they're problem-prone. BUT with the "check gauges" light coming on, my bet is you're experiencing the warning signs of imminent fuel pump failure. gas gauge been bouncing or not reading accurately?

Jun 23, 2009 | 2004 GMC Envoy

1 Answer

Very Light Printer on HP Color LaserJet 3500


Table 7-33. Causes for distortion or blurring
Cause Solution
Transfer unit is defective. Replace the transfer unit. Calibrate the printer
after replacing the transfer unit. See Calibrate
Now, later in this chapter.
Defective secondary transfer roller If it does not rotate smoothly or it is deformed,
replace the secondary transfer roller.
DC controller PCB is defective. Replace the DC controller PCB. Calibrate the
printer after replacing the DC controller. See
Calibrate Now, later in this chapter.

Calibrate Now
Use the following procedure to calibrate the printer whenever you replace the DC controller,
the formatter, the color misregistration sensor (PS12), the transfer unit, or the laser/scanner.
1. Press to enter the MENUS.
2. Press to highlight configure device.
3. Press to select configure device.
4. Press to highlight PRINT quality.
5. Press to select PRINT quality.
6. Press to highlight CALIBRATE NOW.
7. Press to select CALIBRATE NOW.
8. Wait for the printer to calibrate.
hope this helps
pdouglasss

Dec 17, 2008 | HP Color LaserJet 3500 Printer

Not finding what you are looking for?
Reddy Heater-170,000 BTU Kerosene Deluxe Logo

62 people viewed this question

Ask a Question

Usually answered in minutes!

Top Reddy Heating & Cooling Experts

Paul Carew

Level 3 Expert

3489 Answers

Superior Maintenance

Level 2 Expert

67 Answers

Brad Scarpetta

Level 2 Expert

104 Answers

Are you a Reddy Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...