From another Fixya answer:
If you are talking about error code 59 then the error is E.HybC.
E.HybC means that the feedback card on the inverter has been changed.
You must confirm the change at parameter ec.0 or ec.10. The inverter reads the value from the feedback card so all you have to do it hit enter to confirm the value.
If you have not changed the feedback card but the error continues to come back then there is a problem with the feedback card or the control card.
Best option would be to contact manufacture of the machine that the KEB Combivert is installed in for assistance. This way you will be sure to operate the system within the design specifications of the machine.
The CP mode parameters are a small list of parameters that are mapped from the application parameters. Not knowing what you are trying to do with the inverter, it is very difficult to tell you what needs to be programmed.
90% of the machines that us the KEB inverters use the application parameters to gain the full functionality of the inverter.
The machine manufacture whom built the machine that the inverter is installed in should be able to provide you with parameter settings.
×