Makes hollow clear ice. Creates water in ice bin which causes thick layer of ice in bottom of ice bin. Dealer has worked on the problem with a new U-Line service bulletin about this problem. Water supply is RO system water, but this caused no problem with the previous U-Line connected to it, nor does it cause a problem with a SubZero refrigerator connected to the water supply.
Thanks for your help.
2 things you need to check. If you remove the icebucket look for armaflex the goes on the sensor tube from the icemaker to the back wall. If missing call U-line to get the correct one. The second thing you can do is check the icemaker control. Remove the grill, on the base in the right corner you will see a control with a screw. Turn the screw all the way to the right then back it so it will be straight up and down.That will set it cooler