Mini Hi Fi LG FA 162, doesnt power on and has te IC STR-A6252 blown up. What can cause this IC to blow? many thanks
SOURCE: I need a owners manual for a Sony Mini Hi-Fi
Hi,
Click Sony Support to download user manual of MHC-GX250
Thanks.
• Main motor/drive malfunction
• Transfer belt contact clutch defective
• Transfer belt position sensor
defective
• Harness disconnected
The following conditions will cause the Protection LED to go on:
• Initial power-up: For approximately five seconds after initial power-up, the
protection circuitry is activated and the speaker output is muted. If everything is
operating normally, you will hear an audible click at the conclusion of this brief
period, as the protection circuitry is deactivated and the S1500 / S2000 begins
delivering signal to connected speakers (at which point you'll hear a click). It is
normal for the Protection LED to fade gradually after the amplifier is powered off.
• Overheating: A temperature sensing device in the S1500 / S2000 will cause
the protection circuitry to be activated (and the Protection LED to go on)
whenever the operating temperature of the unit rises above a safe level. To
guard against this problem, make sure the S1500 / S2000 receives adequate
ventilation on all sides and that both the front and rear panels are unobstructed.
• Severe overcurrent conditions: This occurs whenever the signal being input to
the S1500 / S2000 rises to a level above 20% THD (Total Harmonic Distortion).
• Shorted speaker cables: This will occur if, due to faulty wiring, the hot and
ground signals being output by the S1500 / S2000 short one another.
• Output impedance drops below 2 ohms: This can occur if the S1500 / S2000
is connected to inappropriate speaker systems (see the "Setting Up and Using
Your S1500 / S2000" section on page 5 in this manual for more information).
• DC voltage detected at speaker output: The most likely cause of this is an
internal failure.
In general, any time the Protection LED lights up (other than during the
approximately five seconds following initial power-up), there is reason to be
concerned. If this occurs, turn the S1500 / S2000 off immediately and carefully
check all wiring and external devices in order to locate and correct the condition
that caused the LED to light up in the first place.
For further assistance, contact your local Samson dealer. If purchased in the
United States, you can call Samson Technical Support (1-800-372-6766)
between 9 AM and 5 PM EST.