136. (10001000) Motor Stall
The Motor Control Module has been unable to start the motor. Possible causes of this fault
are: Faulty motor harness, faulty or jammed motor, seized bearings or seals, faulty Motor
Control Module, faulty Rotor Position Sensor or harness.
Primary Source: Wiring.
Action: Measure/check the motor harness, connectors and motor for
discontinuity. This can be done by taking a resistance measurement
between phases of the motor harness at the Motor Control Module
end. Nominal resistance should be around 32Ohms.
Secondary Source: Motor.
Action: 1) Check free rotation of the agitator and basket by rotating by hand.
Bearings and seals may be seized.
2) Check the Rotor Position Sensor and associated harness for
water, mechanical damage or corrosion.
Tertiary Source: Motor Control Module.
Action: If the primary and secondary checks pass inspection, then replace
the Motor Control Module.