I am facing the error code E000021-0001 how to solve this problem
SOURCE: Cannon IR5055n E000732-0001 Error codes how can I
error codes for canon 5055 photocoping machines
SOURCE: my canon IR 3100 CN
E004
The main thermistor (TH1) has an open circuit or has poor contact. The sub thermistor (TH2) has an open circuit or
has poor contact. The thermal switch (TGP1) has an open circuit. The main heater (H1)/sub heater (H2) has an open
circuit. The AC driver PCB is faulty. The DC controller PCB is faulty.
E004 0001 protection circuit error of the fixing unit
Description: A short-circuit is detected in the triac (for 1 sec or more continuously) while the heater remains off (hardware detection) for 40 msec continuously.
Remedy: Turn off and then on the main power supply.
Remarks: fixing assembly triac malfunction/13V power supply error