20 Most Recent Utilitech 1/2 HP Convertible Jet Pump 1/2C-JET Questions & Answers

0helpful
1answer

Where do the wire leads connect to the switch?

Look on the id plate on the motor, and inside the cover on the back and inside the switch cover.
12/11/2016 2:33:18 AM • Utilitech 1/2 HP... • Answered on Dec 11, 2016
0helpful
1answer

I just purchased a utlitech 1/2 hp convertible jet pump. When I turn it on it just hums.

I The hum is the sound created by a motor when it cannot start either because the load is excessive and it cannot do the job or if the start capacitor is bogus. If cap is good, motor should start immediately upon turn on. Measure cap with cap meter or simply replace it. The capacitance should be the amount indicated on the cap and not more than 10 percent less. If capacitor is good the pump itself might be frozen. Try running the motor not connected to the pump.
8/29/2015 5:28:39 PM • Utilitech 1/2 HP... • Answered on Aug 29, 2015
0helpful
1answer

I have a UtiliTech 1/2 HP Jet pump #0003124. I need a manual. Can I get a larger volume impeler for this mode?l

Put a vacuum gauge on the suction, see if it goes real low after pumping a couple of gallons. If so, your point may be stopped up. A 1/2 hp pump should pump 40/50 psi, fill a 5 gal bucket in a minute or so.
8/28/2015 6:02:06 AM • Utilitech 1/2 HP... • Answered on Aug 28, 2015
0helpful
1answer

I woke up to no water my pump kicks on and hums for 3 to 5 seconds and quits

It sounds like it is seized with the overload relay cycling it to save the motor. It needs to be dismantled, cleaned and possibly rebuilt. Check the price of a new one it may be cheaper.
6/13/2014 6:52:08 PM • Utilitech 1/2 HP... • Answered on Jun 13, 2014
0helpful
1answer

How do I tell the pump to shut off when up to pressure?

The black cover on the side is the pressure switch. Open it you will see two screws with springs on them. Don't touch the short one. The tall one will adjust the pressure. Clockwise for more, counterclockwise for less. Cover should have diagram.
5/11/2014 12:58:02 AM • Utilitech 1/2 HP... • Answered on May 11, 2014
0helpful
1answer

Where can I get utilitech pump parts for #0313833

Utilitech replacement parts:
Customer service 1-866-994-4148
2/7/2019 6:50:37 AM • Utilitech... • Answered on Feb 07, 2019
0helpful
1answer

Sump pump will not pump water, won' turn on, floater up

There are a few things that could cause this problem to come up. Pretty much all of them do require taking the sump pump apart a bit though. I would suggest having a professional come to help you if you don't have much experience with this kind of work. Hopefully you can get this resolved fairly quickly. http://www.rite-waywaterproofing.com/sump_pump_install.php
3/23/2016 9:46:26 PM • Utilitech... • Answered on Mar 23, 2016
0helpful
1answer

View Pump # 0313504

Are you trying to view it, once it has already been installed? If that is the case, you will have some trouble. You will need to call a professional (preferably the installer) to come help you. You might even need a snake camera. Elisa Jed ' http://www.wellservicetampabay.com/Pump_Repair_Brooksville_FL.html
8/26/2014 3:04:11 PM • Utilitech... • Answered on Aug 26, 2014
0helpful
1answer

Utilitech pump wont build pressure

my pump does not hold pressure when the water is running cuts on at 20psi and the pressure keep droping.
8/18/2014 10:42:12 PM • Utilitech... • Answered on Aug 18, 2014
0helpful
1answer

New utilitec pump cuts on and off, won't hold pressure

I do not know your system however it sounds like it is on a well system. If so the pressure tank is water bound and needs to be drained. There is a air regulator that needs repair or replacement. I am just taking a guess.
8/18/2014 10:39:13 PM • Utilitech... • Answered on Aug 18, 2014
0helpful
1answer

I have a pump #WO313834UTPQP1W

Hi Tata, There is no match appearing across the web for that identification number of your pump. There may be character missing or swapped. Please verify the support information. Here is a link offering the pumps at replacement cost which may be more viable looking at the price and effort you may invest in the repairs. Take a look. utilitech parts for pumps BuyCheapr com . At the bottom of the page above, a variety of options exist. Below is one of them Here is a resource further in on the first sight to examine Top Results for pump parts Happy wrenching. Fare. Well.
6/25/2014 7:57:59 PM • Utilitech... • Answered on Jun 25, 2014
0helpful
1answer

Pool pump # 0313504 1.5 hp need part crack top w

Not exactly sure of what you are looking for gut go to: http://www.ebay.com/itm/Strainer-Lid-Cap-and-O-Ring-for-Utilitech-0313509-0313504-69010-001-/360399194824 I think that is what you are looking for.
6/17/2014 10:36:54 PM • Utilitech... • Answered on Jun 17, 2014
0helpful
1answer

What should the pressure be set at

It sounds like a shallow well pump. Normally they would be set to turn on at 20 PSIG and off at 40 PSIG.
6/16/2014 6:18:35 PM • Utilitech... • Answered on Jun 16, 2014
0helpful
1answer

Which way should the motor turn on a 1 HP pool pump

Clockwise,
6/14/2014 10:53:46 PM • Utilitech... • Answered on Jun 14, 2014
0helpful
1answer

My utilitech shallow well froze breaking the rear flang tetween motor and pump need flang how do i order one

It would probably be easier just to get a new pump. There is two flanges that mate, one on the motor one on the pump. I believe it is called a "C" face on the motor but I am not sure. You can get replacement motors with this flange.
6/13/2014 7:11:21 PM • Utilitech... • Answered on Jun 13, 2014
0helpful
1answer

Broken rear pump flang that supports the motor

Best solution is to replace it.
6/13/2014 7:09:24 PM • Utilitech... • Answered on Jun 13, 2014
0helpful
1answer

Parts

You can go to: http://pdf.lowes.com/installationguides/819161011011_install.pdf and get the part number from the manual. It is not in English however there are drawings etc. Also stop at your local LOWS store.
6/7/2014 3:56:14 PM • Utilitech... • Answered on Jun 07, 2014
0helpful
1answer

Pump does not hold pressure

Sounds line a problem with the water source. A lot of information is needed to answer your question such as model number etc.
6/7/2014 3:44:50 PM • Utilitech... • Answered on Jun 07, 2014
0helpful
1answer

Pump just hums-no output

Make sure it's getting water to it.
5/30/2014 11:21:37 PM • Utilitech... • Answered on May 30, 2014
Not finding what you are looking for?
Utilitech 1/2 HP Convertible Jet Pump 1/2C-JET Logo

11 questions posted

Ask a Question

Usually answered in minutes!

Top Utilitech Plumbing Experts

 Mikey
Mikey

Level 3 Expert

6904 Answers

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you an Utilitech Plumbing Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Utilitech Plumbing

  • Utilitech Plumbing

Most Popular Question

just purchased utlitech 1 2 hp

  • Plumbing