20 Most Recent
Delfield 18672PTB Commercial Refrigerator Questions & Answers
The delfield box 18672ptb has
my chart says 32 ounces of R-404 A. Remember, cap tube systems are charged by super heat and TXV systems are charged by subcooling or full sight glass if system has receiver.
2/18/2011 4:32:44 AM •
Delfield...
•
Answered
on Feb 18, 2011
Mod 18672ptb defeild Pizza prep
the tubes that circulates the freon gas to that unit is not working... check for any leakage in gas or check for any blocks in the unit... make sure the compressor is working good...
8/11/2010 11:16:10 PM •
Delfield...
•
Answered
on Aug 11, 2010
Need to repair a pluged cappilary tube
Your best bet is to order an OEM capillary tube and replace it. Of course this requires recovering the refrigerant. The likelihood of unplugging one is very very slim unless it is a very large bore tube.
11/21/2019 9:22:22 PM •
Delfield...
•
Answered
on Nov 21, 2019
Superheat subcooling
the model says that this is a cooler/freezer combination unit. super heat has to be measured on each section separately. As a general rule: Freezers run around 6-8 degrees and coolers are 8-10. I have seen freezers go as low as 4 degrees right before they hit set point temp and shut off.
6/29/2017 2:16:26 AM •
Delfield...
•
Answered
on Jun 29, 2017