Hoshizaki KM255BAH Self Contained Ice Cube Maker Air Cooled Questions & Answers
E1
High temperature alert E1 code occurs if box temperature has exceeded 18DEG F above the set point for more than 2 hours. It will reset its self after temp drops
10/6/2014 4:12:13 PM •
Hoshizaki...
•
Answered
on Oct 06, 2014
Water pressure regulator
need model and serial numbers. I am assuming it is water cooled.(?) let me know more and we can try to fix
8/14/2014 2:29:10 AM •
Hoshizaki...
•
Answered
on Aug 14, 2014
Makes small cubes
this is usually due to the reservoir loosing water or the float is not set right. during the freeze cycle, look for the machine drain and see if any water is draining. start there and let me know if I can help any further.
8/14/2014 2:08:23 AM •
Hoshizaki...
•
Answered
on Aug 14, 2014
Kml 250mah
some over flowing is ok as long as it does not go into the ice bin. if it is, the drain in the res is restricted some how, or the pump is not pumping the water out. start with that and let me know
8/14/2014 1:57:10 AM •
Hoshizaki...
•
Answered
on Aug 14, 2014
Hoshizaki KM-630MAB
Check your refrigerant pressures during harvest. The board is picking up a fault. You could have a thermister problem on the suction line.
7/26/2014 2:33:22 AM •
Hoshizaki...
•
Answered
on Jul 26, 2014