Furnace control board fails
possible burner tube blockage or flame sensor dirty or bad when fails see if voltage to keep gas valve open
Goodman CK30-1t - what fan blade?
You can carefully drill out the motor shaft starting with a tiny bit and gradually increasing size. Using caution not to damage blade hub. Once a good portion is gone you should be able to get blade of shaft.
Gurgling sound goodman awuf240516ba troubleshooting
Trap has gone dry on the indoor unit drain or no trap is installed. If trap is present, fill the trap with water either from a clean out, if installed, or take the door off and pour water in the drain pan and let it run down.
If no trap installed, install P-trap. This is a draw-through coil so it needs a trap.