Kenmore 53642 / 53644 Side by Side Refrigerator - Page 2 - Answered Questions & Fixed issues

0helpful
2answers

Need to Install a Supco 3 n 1 start capacitor

3 in 1 starters like the supco that you have pictured can and will cause premature failure of your compressor. newer compressors are not designed to handle the start up current the 3-n-1 provides. I reccomend replaing wiht an original oem part the part number is 8201786. If you still want to use the hard start use the 410 model obviously hook up the red white and blak wires to the compressor the 2 left over leads will connect to the 2 original wires that come in to the compressor I beleive they are red and white. polarity does not matter. good luck Peyton
4/1/2013 10:51:25 AM • Kenmore 53642 /... • Answered on Apr 01, 2013 • 9,273 views
0helpful
1answer

Replace water line in freezer door

Do you have a model number?
3/14/2013 3:24:19 AM • Kenmore 53642 /... • Answered on Mar 14, 2013 • 197 views
0helpful
2answers

Water dispenser will not work

This could be a bad water valve in the frig. This frig has a double water valves. One for the ice maker and one for the water dispenser. It should be in the lower back. Where the water line goes in. You can check this valve easily. Find the double water valve on the frig. Turn off water supply to frig first. Swap the plastic water lines going from the water valve into the frig. Turn water supply on. Then see if the water dispenser works. Sometimes you will have to operate the water dispenser for a little while to get the air out of the line. If it works now then the problem is in the water valve solenoid and needs to be replaced.
3/6/2013 1:42:32 AM • Kenmore 53642 /... • Answered on Mar 06, 2013 • 334 views
0helpful
1answer

Kenmore refridge ice release not working model 59287990

cant get ice to despence threw door
1/26/2013 9:35:43 PM • Kenmore 53642 /... • Answered on Jan 26, 2013 • 253 views
0helpful
2answers

I have a side by side Kenmore fridge with ice

The ice maker has two 1/4 inch sheetmetal screws holding against the wall upper left and one underneath the maker. Remove these and it should come out
12/15/2012 2:31:09 PM • Kenmore 53642 /... • Answered on Dec 15, 2012 • 801 views
0helpful
1answer

Kenmore 10653703202

dont have the solution but the same problem....i would also like to know how to test these parts, i already changed the thermostat, that wasnt it... the model number is 10653703202
11/19/2012 9:17:52 PM • Kenmore 53642 /... • Answered on Nov 19, 2012 • 65 views
0helpful
1answer

Kenmore model 596.57542791 side-by-side leaks from

water started dripping from the bottom of the freezer door.
9/27/2012 3:47:32 PM • Kenmore 53642 /... • Answered on Sep 27, 2012 • 152 views
0helpful
1answer

How do I gain access to door chute on kenmors 106.59129801

The first thing to do is unplug the machine. After that slide out the area where the water falls, I guess you would call that a drip pan, and place to the side. Now, the part that always makes me uncomfortable, you're going to have to pop the trim off the door. Its held on by little clips, and the method I found most succcessful without damging the trim or breaking the clips is to get a small flathead screwdriver, and just above the lower corner, either one, slide it in between the trim and the door and kind of pry it forward. Once you get started its down hill from there. After you get the trim off, you'll be able to remove the control area, which is either held in by screws or sometimes tabs, and access the flap. Note that alot of times the door flap is fine, its a plastic little ring that is broken on the mold of the door. In the past you had to buy the whole door,which ran about $700, but now there is a repair kit, which cost me whole sale no more than $50, so retail about $70 or so I would assume. There are other parts in the area that helo the machine function, such as the soleniod that connects to the flap to help open or shut it, retaining bracket, and so forth. Once you have the dispenser apart it shouldn't take long to isolate the problem. If you need further help, I’m available over the phone at https://www.6ya.com/expert/jason_4570d45317834dd3
6/5/2012 6:25:29 AM • Kenmore 53642 /... • Answered on Jun 05, 2012 • 93 views
0helpful
1answer

How long should my refrigerator run before stopping

That depends on the what the temperature is set at, but regardless, the timer will shut it off every 6 or 8 hours, depending on which timer you have to defrost. The most common cause though of excessive running is that the machine is low on freon and never actually reaches the temperature set. If this was the case normally you will see a reduction in ice production as well. If you need further help, I’m available over the phone at https://www.6ya.com/expert/jason_4570d45317834dd3
6/2/2012 8:39:48 AM • Kenmore 53642 /... • Answered on Jun 02, 2012 • 63 views
0helpful
1answer

Water leaking from dispenser

CHECK WATER LINE EASY TO REPLACE CHEAPLY
5/9/2012 1:49:48 AM • Kenmore 53642 /... • Answered on May 09, 2012 • 43 views
0helpful
1answer

Both the freezer and the fridge are cold on the bottom but not on the top.(?????????)

Check your fan is operating and that your top cooling tubes aren't frosted up.
1/15/2012 10:34:57 AM • Kenmore 53642 /... • Answered on Jan 15, 2012 • 256 views
0helpful
2answers

I have a Kenmore side-by-side, model 253 54364405.

washerwill not spin
10/29/2011 1:23:59 AM • Kenmore 53642 /... • Answered on Oct 29, 2011 • 590 views
0helpful
1answer

We have a kenmore fridge

NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.
First I would check cold control. Thats where you turn it off, if your temp is not warm. it can
be defective and not shutting off. If your temp is warm proceed with the following.
I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if FREEZER CONTROL is turned WARMER WHICH MAKES THE REF COLDER AND VICE-VERSA. SEE?
The ref. temp should be about 33-35
The Freezer temp should be 0 to 10 Any thing below these temps is overkill and a waste of elect
The higher the number you turn it up to is the coldest
But is probably a common defrost problem The ice build up
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
Make sure back cover is on the fridge. Some take them off and throw them away.
make one out of cardboard if its gone, using the holes of the old one.
.I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

If you need more help go here:

http://www.applianceaid.com/procedures.html

MORE
TIPS AND TRICKS:
-----------------------------------------------------------------------------------------------------
STOP PAYING FOR EXPENSIVE WATER FILTERS FOR YOUR REF. DO THIS====
http://www.fixya.com/support/r9962087-stop_paying_high_price_refrigerator
-------------------------------------------------------------------------------------------------------
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
----------------------------------------------------------------------------------------------------------------------
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.
9/26/2011 12:58:30 AM • Kenmore 53642 /... • Answered on Sep 26, 2011 • 75 views
0helpful
1answer

There is reddish (rusty) leak

Sounds like there is a lot of iron in the water.
Go to www.applianceart.com and look through their fridge cover options.

They have magnetic and vinyl. Vinyl seems like the best option. It will cover the rusty coloring and protect the surface from further problems. They will even custom make covers for you. All you need is an idea and measurements.

http://www.applianceart.com/category_s/51.htm
9/23/2011 2:33:11 PM • Kenmore 53642 /... • Answered on Sep 23, 2011 • 57 views
0helpful
1answer

I have a side by

FREEZER FAN MOTOR MAY NEED REPLACED. THE EASIEST WAY IS TO TAKE OFF THE BACK PANEL IN FREEZER AND REMOVE THE FAN
MOTOR, TAKE IT TO THE NEAREST APPLIANCE PARTS STORE WITH YOUR MODEL NO.
EASY JOB.
I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

need more help go here:

http://www.applianceaid.com/procedures.html

MORE TIPS AND TRICKS:
-----------------------------------------------------------------------------------------------------
STOP PAYING FOR EXPENSIVE WATER FILTERS FOR YOUR REF. DO THIS====
http://www.fixya.com/support/r9962087-stop_paying_high_price_refrigerator
-------------------------------------------------------------------------------------------------------
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
----------------------------------------------------------------------------------------------------------------------
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.
9/19/2011 3:29:10 PM • Kenmore 53642 /... • Answered on Sep 19, 2011 • 68 views
0helpful
1answer

The freezer of out Kenmore

Hi welcome to fix-ya. Sounds like a defrost problem. Do you have frost on back panel? If so Take a hairdryer and thaw the coil. If this fix works for you. You have a defrost problem. The hairdryer will buy 7-10 days You may need a new clock or board Sears will be the place to go I hope this helps.
9/10/2011 4:06:33 PM • Kenmore 53642 /... • Answered on Sep 10, 2011 • 68 views
0helpful
2answers

The divider between the side by side

The divider between the side by side frigerator/freezer where the door closes and seals is extremely hot- too hot to touch. Is something wrong with my refrigerator, should i unplug it?
9/7/2011 5:40:56 PM • Kenmore 53642 /... • Answered on Sep 07, 2011 • 1,759 views
0helpful
1answer

Freezer is working fine the

NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.
First I would check cold control. Thats where you turn it off, if your temp is not warm. it can
be defective and not shutting off. If your temp is warm proceed with the following.
I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if FREEZER CONTROL is turned WARMER WHICH MAKES THE REF COLDER AND VICE-VERSA. SEE?
The ref. temp should be about 33-35
The Freezer temp should be 0 to 10 Any thing below these temps is overkill and a waste of elect
The higher the number you turn it up to is the coldest
But is probably a common defrost problem The ice build up
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
Make sure back cover is on the fridge. Some take them off and throw them away.
make one out of cardboard if its gone, using the holes of the old one.
.I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically
If
you need more help go here:

http://www.applianceaid.com/procedures.html

MORE
TIPS AND TRICKS:
-----------------------------------------------------------------------------------------------------
STOP PAYING FOR EXPENSIVE WATER FILTERS FOR YOUR REF. DO THIS====
http://www.fixya.com/support/r9962087-stop_paying_high_price_refrigerator
-------------------------------------------------------------------------------------------------------
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
----------------------------------------------------------------------------------------------------------------------
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.
9/6/2011 2:13:47 AM • Kenmore 53642 /... • Answered on Sep 06, 2011 • 45 views
0helpful
1answer

Kenmore elite. model # 106.54606300. icemaker not

What is the part number for the walter filter on this refrigerator?
8/29/2011 1:10:52 AM • Kenmore 53642 /... • Answered on Aug 29, 2011 • 626 views
0helpful
1answer

Refrigerator will not cool below

Hi,

Check out these tips...they can help you figure out what is going wrong withyour refrigerator and why it is not cooling

Refrigeratornot Cooling or Fridge not Cooling

How to Defrost Refrigerator DefrostTimer Problem

WaterRunning in refrigerator from Freezer

Refrigeratoror Freezer not Cooling or Getting Cold
heatman101
8/28/2011 12:49:20 AM • Kenmore 53642 /... • Answered on Aug 28, 2011 • 547 views
Not finding what you are looking for?
Kenmore 53642 / 53644 Side by Side Refrigerator Logo

733 questions posted

Ask a Question

Usually answered in minutes!

Top Kenmore Refrigerators Experts

vince

Level 3 Expert

2530 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Johnny 1000

Level 2 Expert

94 Answers

Are you a Kenmore Refrigerator Expert? Answer questions, earn points and help others