Top 20 Kenmore 55612 / 55614 / 5561 / 655619 Side by Side Refrigerator Questions & Answers

1helpful
1answer

Kenmore elite 106.5770 ice auger motor is out.

This is probably one of the best videos I have ever found on replacing auger motors...at least how to access them in Kenmore units. I hope this helps you with your issue.
11/28/2017 3:15:03 PM • Kenmore 55612 /... • 1,475 views • 1 helpful votes
0helpful
1answer

Model #253.54739304. My ice maker works fine but

Your fridge was made by Frigidaire / Electrolux corporation for Sears Kenmore. This is the parts manual for your model. http://b2b.frigidaire.com/support/ResultsPage.asp?strModel=253.54739304&User=&Search=Search ftp://ftp.electrolux-na.com/ProdInfo_PDF/Anderson/5995400073.pdf
10/25/2017 7:51:03 AM • Kenmore 55612 /... • 248 views • 0 helpful votes
0helpful
1answer

Freezer freezing great, Fridge running warm

Hello Murr9, The number 1 reason a freezer "SEEMS" to be working... but the refrigerator isn't cutting it... is PROPER AIR FLOW... look through the vents in the back of the freezer section... If you see thick frost or ice... you have found your trouble If the evaporator fan (behind the freezer wall is operating at ANY speed your REFRIGERATOR section would be adequate... You had a repair person out... but while that ought to mean something to me... I would rather you do some simple checks... - Look through those vents - You need to check the defrost pan... DRY means you have troubles... put a piece of fresh typing paper inside the pan... fold it over the edge... if it is still dry the next day... Your defrost circuit is broken... It only has three components: - heater element - defrost thermostat (opens at room temperature) - Printed Circuit Board Your refrigerator DOES NOT have a defrost timer... but rather a PC Board... ($152, see below... plus how to video)... Most expensive part but easiest to replace... Important - Important - Important TAKE PICTRES OF ALL THE WIRE connections BEFORE you start. http://www.appliancepartspros.com/whirlpool-timer-defrost-4388932-ap3109394.html Get on AMAZON and buy yourself a couple of the TAYLOR REFRIGERATOR thermometers... zero Fahrenheit is fine for the FREEZER... REFRIG should be just above 32 degrees Fahrenheit... Amazon com Taylor Freezr Refrig Thermometer 1 pack of 3 items Home Kitchen partsselect PartSelect Appliance Parts and Repair Help repair clinic Appliance Parts Lawn Mower Parts Heating Cooling Parts 365 day returns
3/4/2017 12:27:02 AM • Kenmore 55612 /... • 905 views • 0 helpful votes
0helpful
1answer

How do I replace a plastic auger with a metal auger in a Kenmore side by side?

Fridge Dispenser Auger Drum Replacement - Whirlpool ...

? 4:56 www.youtube.com/watch?v=-fUJlQ1BQcs Apr 12, 2013 - Uploaded by RepairClinic.com The most common reason for replacing the dispenser auger drum is when ... Whirlpool, Kenmore, KitchenAid, Roper, Estate, Maytag, Crosley, ...
9/23/2015 4:46:00 PM • Kenmore 55612 /... • 303 views • 0 helpful votes
0helpful
1answer

Why would food in the refrigerator side freeze?

probably your Damper unit! In the fridge section is a hit and miss type vent using a motor to open and close via PCB temp sensor!
10/7/2015 6:38:57 PM • Kenmore 55612 /... • 189 views • 0 helpful votes
0helpful
1answer

My Kenmore side by side Refrigerator Model 795.5103 fridge door squeaks...how can be fixed...?

Have you tried oiling the hinges? You could use cooking oil for this.
3/2/2015 4:58:49 AM • Kenmore 55612 /... • 190 views • 0 helpful votes
0helpful
1answer

What is the fix for warm water out of dispenser

Would that not be covered by the manufacturer & also in your manual
10/8/2014 6:43:19 AM • Kenmore 55612 /... • 107 views • 0 helpful votes
0helpful
1answer

Cubic feet of kenmore #106.55603400

Please type the site "Sears Parts Direct "into your search engine, and you will get a website with a phone number you can call for help, they should have that answer for you. God bless your efforts.
6/21/2014 2:28:32 PM • Kenmore 55612 /... • 855 views • 0 helpful votes
0helpful
1answer

Freezer side is working and refrigerator side is not on my kenmore side by side refrigerator

It is a typical defrost problem. I totally agreed with answer 3 - 4 - 5 !!! Good luck
8/14/2014 4:19:15 PM • Kenmore 55612 /... • 108 views • 0 helpful votes
0helpful
1answer

Kenmore side by side freezer is freezing up and refrigerator is not cooling model 58582890

Fridge freezing up- and no fan or air circulation: AT TIMES The fan usually stops working due to ice obstruction when the defrost terminator has gone out and u get ice build up? u can check the terminator with a multi meter for continuity but do not check at room temperature. stick the terminator in cup of ice water for 20 minutes then check it for continuity, should be closed when cold and open at room temperature. May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad? Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next. Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance.. Another item to check with a meter is the heating element itself. Located under the evaporator coils. It should show continuity or resistance OHMS WHEN TESTED AT BOTH ENDS OF THE PRONGS . Lastly check the cold control thermostat with a meter for both OHMS and volts ( VOLTS is a live test with fridge plugged in so be careful) It must show 110 volts. An open or thermostat that reads infinity will not allow the proper cooling and defrosting cycles to operate and may in fact stop anything from happening as if there is no power to the unit? ALSO CHECK THE AIR FLOW VENT SYSTEM At times it can get stuck to far closed or open. Some units feature a digital electric adjusting vent system while others are manually set. Check for any ice build up or other obstruction in the vent damper, see if u can manually open or close it. Some times when u have the settings set to the highest it closes off one area while allowing to much cold air flow to the other area!
6/29/2014 6:10:25 PM • Kenmore 55612 /... • 150 views • 0 helpful votes
0helpful
1answer

Kenmore 10657575791 changed water valve selonoid still not filling

water line maybe clogged. Check. Do you have the proper waterline pressure?
7/7/2014 4:32:04 PM • Kenmore 55612 /... • 99 views • 0 helpful votes
0helpful
1answer

Freezer workd top frig not working

FREEZER /FRIDGE NOT COOLING: Optimum refrigerator temperature at or below40° F(4° C). The freezer temperature should be0° F(-18° C). Check temperatures periodically. Appliance thermometers are the best way of knowing these Check ur cold control thermostat, ur thermistors in both fridge and freezer ( they should be checked for both ohms and for amount of current being put out as per ur model ), ur air flow vent from freezer to fridge.( to make sure it opens and closes without any restrictions) On thermistors check for A close circuit and amount of ohms not just an Ohm reading. As per ur model. Most should atleast show 1200 ohms. Also Check door seals for leakage. Evaporator coils Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited. FAN check to see if it is operating or restricted A fan that is not blowing or restricted will not circulate the cold air properly. Often, the first thing that folks do when their refrigerator starts to feel warm is turn both controls on the coldest settings.This is exactly the WRONG thing to do.Turning the cold control to the coldest settingwillkeep the compressor running longer and make lots of cold air. But turning the air door to the coldest settingclosesthe airway to the food section. Lots of cold air is made, but most of it stays in the freezer section, and the food section actually getswarmer. Condenser Self-defrosting refrigerators all have a set of coils and a cooling fan, usually under the refrigerator, that need to be cleaned regularly. If these coils get coated with dust, dirt or lint, the refrigerator may not cool properly. The coils may appear to be a thin, black, wide radiator-like device behind the lower kick-panel. To clean them, disconnect the refrigerator from the power source, use a refrigerator condenser brush and your vacuum cleaner to clean the coils of any lint, pet hair, etc. You may not be able to get to all of the condenser from the front, it may be necessary to clean the remainder of the condenser from the rear of the refrigerator. May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad? Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next. Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance.. THE COMPRESSOR: If you hear a clicking sound coming from the back of your refrigerator/freezer, then the problem is most likely the compressor, relay and or capacitor is overheating or not getting proper power and will not start.The compressor is the component on your refrigerator that allows your refrigerator to cool. If this component is not working properly your refrigerator will stop cooling. Most of the time the compressor is not the component that has failed. To check ur compressor with multi meter: Disconnect and remove the relay and capacitor from compressor, somes located next to compressor in a casing. You wills see 3 prongs coming out of compressor. 1 goes to ur srtart winding, 1 goes to ur run winding and the center goes to ur ground. Place ur meter connector or prong on the start prong and the other on the ground (center prong) take note of the reading in OHMS for example 5 ohms. Next place meter prong on run prong and the center ground prong agin. Take note of the reading in OHMS. Example 4 ohms Next place meter prong on the start prong and the other on the run prong, now take note of the reading example 9 ohms. Now match the total of this ohms test with the total of ur two separate test. 9 ohms, if they match ur ok give or take 5 percent plus or minus. One more test to make to test of there is a short in compressor attach meter prong to ground prong and rub the other end of meter prong to metal ( scrape the metal clean of paint and test on metal surface not painted surface. If it shows continuity or ohms , u have a short in ur compressor. It should show infinity Lastly you should also check ur THERMISTORS in the freezer and fridge section for continuity OHMS and for amount of OHMS current being put out. In most models around 13000 ( give or take 150 ohms) ohms is required. Read more:http://removeandreplace.com/2013/10/31/fix-refrigerator-freezer-wont-cool-freeze/#ixzz3WDEo5NDJ
7/7/2014 10:38:39 PM • Kenmore 55612 /... • 83 views • 0 helpful votes
0helpful
1answer

I have a Maytag refrigerator model MTB2176HR. Both the fridge and the freezer are no longer cold. I also hear a clicking sound approximately every minute odr so. It sounds like a relay switch being tr

Believe if you replace these parts=> 12002794 Relay and Overload Kit and pay attention to the comments made during the tutorial video you will be fine, Thanks John Tripp Appliance 911
2/13/2014 5:26:59 PM • Kenmore 55612 /... • 494 views • 0 helpful votes
0helpful
1answer

Refrigerator door keeps opening

Check the hinges are tight and seal in correct place to seal and stick. make sure no shelves are out of position stopping the door from closing properly, and lose some weight from the door if you keep lots of heavy bottles in it.
4/21/2014 11:43:43 PM • Kenmore 55612 /... • 79 views • 0 helpful votes
0helpful
1answer

Kenmore side by side freezer not freezing

I have had that problem when my Kenmore frig was surrounded by too much stuff that prevented air flow to the coils. It was also a problem when I had it on carpeting. I put a wood panel underneath the whole frig and cleared away all the clutter.
3/22/2014 5:08:29 PM • Kenmore 55612 /... • 132 views • 0 helpful votes
1helpful
1answer

Popping sound refrigerator

That is normal these sounds are the contractions and expansion of plastics when it becomes very cold or thaws.
1/13/2014 9:39:56 PM • Kenmore 55612 /... • 181 views • 1 helpful votes
1helpful
1answer

Kenmore 106 freezer side wont go below 15 degrees

Did you try it with the manual? Kenmore Coldspot Model 106 Manual
10/22/2013 11:34:17 AM • Kenmore 55612 /... • 365 views • 1 helpful votes
0helpful
1answer

My kenmore refrig. isnt getting cold? the fan works i think the compresser sounds like its working . wont get cold

Try cleaning the coils usually located at the rear of the unit. If the coils are not clean the compressor will not be able to work properly.
12/8/2013 5:03:28 AM • Kenmore 55612 /... • 84 views • 0 helpful votes
0helpful
1answer

I have a Kenmore model number 106.51552104 my ice

I believe I answered this one on another page of unsolved problems HERE. Thanks for the model number. If the ice slots inside the ice maker are empty try pouring tap water in the slots and allow the water to freeze. If after the water freezes the ice drops into the ice bucket and the ice maker does not refill this would indicate that the side of the=> W10408179 Water Inlet Valve is defective on the side that controls ice maker water supply. If the ice maker just sits there and does nothing this would point to a defective ice maker. Depending what is wrong with the ice maker will determine what parts are replaced. Here is a list of those parts here=> Kenmore Refrigerator Model 106.51552104 Ice Maker Parts and if need you may be able to find a complete ice maker replacement by asking. Most people don't like replacing ice maker parts. I am here should you have questions or comments, Sea Breeze
8/30/2013 2:32:20 PM • Kenmore 55612 /... • 1,066 views • 0 helpful votes
Not finding what you are looking for?
Kenmore 55612 / 55614 / 5561 / 655619 Side by Side Refrigerator Logo

1,480 questions posted

Ask a Question

Usually answered in minutes!

Top Kenmore Refrigerators Experts

vince

Level 3 Expert

2530 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Johnny 1000

Level 2 Expert

94 Answers

Are you a Kenmore Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Kenmore Refrigerators

  • Kenmore Refrigerators

Most Popular Question

light bulb stays in kenmore elite fridge

  • Refrigerators