RELIANCE ELECTRIC WATER HEATER - Answered Questions & Fixed issues

0helpful
1answer

606 problems

10/2/2018 7:47:42 AM • RELIANCE... • Answered on Oct 02, 2018 • 445 views
0helpful
1answer

After pushing reset button,how long before water gets hot

About 20+ minutes... full tank of hot will take longer.. put ear against tank and listen if it is heating http://waterheatertimer.org/How-to-troubleshoot-electric-problems-with-water-heater.html
10/2/2018 6:56:09 AM • RELIANCE... • Answered on Oct 02, 2018 • 680 views
0helpful
2answers

I need to replace a reliance 606 50 gallon electric water heater model 65220RT2 What is made the same to simplify installation, wiring, plumbing, etc? Need new heater with hookups for electric and p

April 2015... all water heaters will be larger. I would go to local supplier, and buy off the shelf water heater that is same gallonage and use flexible water connections to make installation easier http://waterheatertimer.org/New-government-water-heater-standards.html http://waterheatertimer.org/How-to-install-electric-water-heater.html Gene Water Heater Timers Save Money If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
9/10/2018 11:32:48 PM • RELIANCE... • Answered on Sep 10, 2018 • 775 views
0helpful
2answers

Need a manual for a maytag electric water heater.

More information is needed about this heater.

The label located on side of tank should show manufacturer.

Maytag does not manufacture water heaters.
Maytag is a brand name used to market water heaters made by other companies.
Maytag offers a phone number for water heaters:1-866-362-9898

Other resources:
-If the water heater has electronic control box on top, then following American Water Heater Company manual might be suitable:
http://www.americanwaterheater.com/support/manuals/energysmart.pdf

-Electric water heater instruction manuals can be found on following link:
Each is basically the same, unless there is electronic control box.
http://www.americanwaterheater.com/support/manuals.aspx

-If you have ordinary two-element 240volt water heater and are having problems, or want information on maintaining water heater, then following link is useful:
http://waterheatertimer.org/DIY.html
http://waterheatertimer.org/Replace-anode-rod.html
http://waterheatertimer.org/Clean-sediment-out-of-water-heater.html#cleanelectric
4/4/2016 10:59:28 AM • RELIANCE... • Answered on Apr 04, 2016 • 405 views
0helpful
2answers

How do i test the themastat on a reliance 606 electric water heater?

There is no reliable test for electric water heater thermostats Replace thermostats http://waterheatertimer.org/How-to-replace-thermostat-on-electric-water-heater.html Gene If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
12/23/2015 12:40:52 PM • RELIANCE... • Answered on Dec 23, 2015 • 563 views
0helpful
1answer

I replaced both elements and both thermostats and water still gets too hot.

there is a small screw in the control panel that sets the thermostat and by turning it anti clockwise you can lower the temperature of the water all to the right is around boiling and all to the left is around 55 degrees c thee is an automatic mixer that you can have fitted to the hot water outlet that is mixed with tap water to control the temperature to prevent scalding accidents it is preset to a temperature at the tap of around 75 degrees C
10/28/2015 10:08:53 AM • RELIANCE... • Answered on Oct 28, 2015 • 303 views
0helpful
1answer

Lower element is not getting any voltage

First check that all connections are good. turn off power and take off the cover plates pull out the wires connected with wire nuts and check that they are not loose remove any electrical tape covering the nuts and turn power back on. with a meter check that you have 220 at the connections. if all is good at the incoming service check the upper element if power passes it in parallel check the exiting connections.if good there check the bottom power if you have 220 there either your element is bad or the thermostat. check the element by turning off power again and check the element with a continuity tester. if the element is good then your thermostat is probably defective try turning it up higher and see if you get 220 out of it.
5/4/2015 4:15:44 AM • RELIANCE... • Answered on May 04, 2015 • 258 views
0helpful
3answers

Water heater supplies about a

Hello Rsjohnson164,

I understand that you are having a problem with your hot-water tank not producing any amount of hot-water. I would suggest that you turn off the cold water supply to your hot water tank and drain the tank and see how much water comes out of it.

Flush the tank:
1. Turn off the cold water supply
2. Hook a water hose to the boiler valve (spicket on the bottom of the tank) and turn on the valve
3. Turn on the cold water inlet line and let it run for about 15 minutes or until you get good pressure coming out.

Check the Elements:
1. Turn off the power to the hot-water tank
2. Remove the service panels
3. Remove one wire from the element and use a multi-meter to check continuity
4. If no continuity replace one or both elements

If you do all of this and still have a problem repost to this thread and we will check your thermostats to make sure they are working properly.

Thank you for choosing FIxYa.com

Justin
1/17/2015 6:07:35 PM • RELIANCE... • Answered on Jan 17, 2015 • 232 views
0helpful
1answer

What causes the water to stink after it comes from the electric heater

the electricity it burns in the water like when u burn trash it stinks becase of the electric
12/18/2014 8:28:34 PM • RELIANCE... • Answered on Dec 18, 2014 • 150 views
0helpful
1answer

How many gallons are ther in a reliance 501 water heater

As near as I can see you have a thirty gallon tank.
12/17/2014 5:03:57 PM • RELIANCE... • Answered on Dec 17, 2014 • 1,482 views
0helpful
2answers

LOWER ELEMENT IS NOT GETTING ANY VOLTAGE ON MODEL

Short answer: Thermostats may be bad. Replace both thermostats.
http://waterheatertimer.org/How-to-replace-thermostat-on-electric-water-heater.html

Long answer:
1) If water heater has some hot water, then upper element is good and water heater has 240Volts, and best suspect is burned out lower element.
http://waterheatertimer.org/How-to-clean-sediment-out-of-electric-water-heater.html

2) If water heater has no hot water because 240volt circuit breaker is tripped on one leg, and only 120Volts is arriving at water heater, then upper part of water heater can appear to have voltage and lower part of water heater can appear to have no voltage.
Open following links for troubleshoot steps:
http://waterheatertimer.org/How-to-troubleshoot-electric-problems-with-water-heater.html
http://waterheatertimer.org/Test-electricity-to-water-heater.html

Add a comment for more help
1/16/2015 4:39:40 AM • RELIANCE... • Answered on Jan 16, 2015 • 1,316 views
0helpful
1answer

Water is leaking out the bottom

4/20/2015 8:19:03 PM • RELIANCE... • Answered on Apr 20, 2015 • 241 views
0helpful
1answer

1994 reliance water heater 501

10/25/2014 8:27:34 PM • RELIANCE... • Answered on Oct 25, 2014 • 606 views
0helpful
1answer

Replacement elements

http://waterheatertimer.org/How-to-replace-water-heater-element.html Use 4500 or lower wattage Any generic brand will work Gene If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
10/25/2014 8:19:09 PM • RELIANCE... • Answered on Oct 25, 2014 • 96 views
0helpful
1answer
0helpful
1answer

How do i test themastat on a reliance 606 water heater?

There is no reliable test. Replace thermostats http://waterheatertimer.org/How-to-replace-thermostat-on-electric-water-heater.html Gene If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
10/25/2014 6:14:53 PM • RELIANCE... • Answered on Oct 25, 2014 • 169 views
0helpful
1answer

Cold water hit the elements and now it keeps tripping the themastat reset button

Replace thermostats. If problem continues, replace elements http://waterheatertimer.org/How-to-replace-thermostat-on-electric-water-heater.html If water heater flooded, replace heater http://waterheatertimer.org/Floodedwater-heater.html Gene If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
4/29/2015 5:00:04 AM • RELIANCE... • Answered on Apr 29, 2015 • 243 views
Not finding what you are looking for?
RELIANCE ELECTRIC WATER HEATER Logo

336 questions posted

Ask a Question

Usually answered in minutes!

Top Reliance Water Heaters Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Paul Carew

Level 3 Expert

3808 Answers

Are you a Reliance Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...