operating properly then you should see something like this: At 80° F the high should read from 277 psi to 295 psi with a clean condenser coil and the low will be about 116 psi to 130 psi or so if
Question about Intertherm Heating & Cooling
...r410a temps in the pink. R22- Most evaporator are good between 40-50°F. If your coil is operating at 45°f your superheat value should be 10°-18°. Take the actual temp of the suction line(large copper ...
suction 115.cant get low side to come up.need to know what should i be checking to figure out why. What freon are you using? Those are the proper operating pressures for R410A. What else is happening