Well if you have a electric tester they sale up at harbor freight cheap Find out if it is getting power or not first then re try sounds like the Motors Shot or shorted out or froze up.
Well, as you probably already know Forest River only carries the on-line manuals for the last three model years. So, if your Rockwood is a 2014-2016 model year you can go straight to the web-site. Older models are out of luck, however, I'd send them an email request and see if they can dig one up out of their archives.
Another good place to try would be owners group forums.
talk with an agent for the manufacturer as to the limits of what can be attached to the unit
as most camper chassis are of light gauge manufacture and any excess weight can cause them to crack and the attachment to fall of
1st Question - Can you verify that you actually have a Gas/Electic Waterheater? Most units are gas only. You may have to look at the unit and look for power cables.
2nd. Is power connected prior to turning on the water heater?
Connect the trailer to the city water supply, turn on the water and open each faucet until clean clear water is present. Don't forget the toilet and outside shower if equipped. Next reinstall the anode rod (suburban) or drain plug (atwood) into the water heater. Go to the back side of the water heater and close the valve on the pipe that connects the cold (bottom line into water heater) and hot (upper line out of the water heater) and then open the bottom cold water line valve and, if equipped, the upper hot water valve. This will fill the water heater. Open the hot water valve at the kitchen faucet. When the water flow is steady the water heater is full and ready for use. If the unit is equipped with a water filer, after all is flushed out, turn the water off and remove the filter housing. Install a new filter and re-secure the housing and turn the water back on. If you are using the fresh water pump, it is possible that the winterizing valve for the pump was left open. If so, close that valve which will divert the pump back to drawing from the tank.
Look behind all cupboard doors higher and lower. Also look for a brown plastic cover in face of cupboards as well. Usually closer to where power cord enters from outside.
Coax or RCA? Coax will screw directly to the terminal on the back of the TV. rca connectors will be red to red, white to white (both audio control) and the yellow will go to yellow or in some cases green. The TV should be labeled video in.
×