the car has 26 relays!@
and 1 to or 3 fans
are you saying the heater/ A.C blower is dead./ the HVAC?
or engine fan (its mech for rad)
or condenser fan,
no symptoms posted, just relay hunts.
my guess is you dont know how the blower in the heater works.
so will cover that.
The HVAC.
First test is blower in high, failing is bad fuse.?
if lower speeds fail, (a top clue) then the blower resistor is bad.
but only on the manual hvac option!
lets backup,I have full parts list on your car, here, USA. spec
the car came new with 2 class type of HVAC
manual AC with blower resistor
or
full auto system that as a new brain box, and a transistor box
that controls blower, at all times, its just a transistor. (no brains)
some cars with the full auto HVAC feature
have a self test mode.
and self calibration feature (learn) all this is in the BIG BOOK.
apples and oranges, different to the extreme.
so instead of me guessing car you bought. ill tell you to RTM
just 4 bucks, and only covers that exact year, and car only.
not a clone book as the folks post here , RAG books.
the real deal here from suzuki actual....
the BIG BOOK. see chapter HVAC and read.
https://suzukipitstopplus.com/Products/1174-2001-grand-vitara-xl-7-service-manual.aspx
×