The HVAC blower became intermittent for about 15 minutes then just stopped working.

I've read the post at:
http://www.fixya.com/cars/t1580493-hvac

I pulled out the blower motor - measured well less than 1 Ohm across the blower contacts.

I measured the voltage across the wire harness connectors to the blower, but even with the switch turned on - I didn't see any voltage on several switch settings. Unfortunately I can't recall if I put the switch all the way to high or not.

Reconnected the wire harness to the blower and tried again - still no movement.

Pulled out the hvac console to clean the contacts on the fan speed switch - boy are those some pesky tabs to pry apart at times! Contacts on the switch didn't look bad, cleaned them a little they look fine now. Placed it back in the dash.

Still not working.

I've looked at the location of the 'resistor card' in the diagram, but I guess I'll have to see if look up underneath the passenger side will even allow me to see the resistor card screws (then I can consider what flex tool I'll need to buy to get them).

What measurements can I take to isolate the problem?
To the resistor card?

  • Marvin
    Marvin May 11, 2010

    try live chat for this one.

×

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

  • Master 543 Answers
  • Posted on Oct 07, 2009
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Joined: Nov 11, 2008
Answers
543
Questions
0
Helped
274380
Points
1601

If the resistor card is bad you will only have setting 4 high on the blower and no other speeds, the resistor card is under the passenger side glove box by the center console way up there, i think its a phillips head,if i remeber right not too hard to get to,,, if no high speed then the fan motor is bad,thats under the wiper cowl under the hood,u gotta remove the wiper cowl to replace it

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

2003 Honda Accord v6 AC and car alarm electrical issues, maybe connected ?

what sub model accord, v6 LX ,
manual or full climate control option??? guess full.
fuses not checked PCM scanned for DTC errors EVAC, hopeless/?
so car starts and runs sand drives ok, <<< not told that.
yes the AC brain on most modern cars is BCM brain controls
and the brain does control the AC compressor. if that is dead so be AC, THE COMPRESSOR CLUTCH, is run by PCM RELAY.
NOT TOLD OUTSIDE TEMPERATURE NOR COUNTRY../
HERE IS A LIST.
1: CHECK ALL FUSES FIRST, CAB AND ENGINE BAY ALL FUSE BOXES SKIP NONE.
2: CHECK IP CLUSTER FOR ERRORS ,ALARMS ERRORS OR LAMPS GLOWING OR IMMO LAMP SHOWS IMMO IS UNHAPPY, MODE.
3: ENGINE STARTS AND RUNS AND CAR DRIVES.?????????
4: HEAD LAMPS WORK KEY ON AND OFF. ,
5: OTHER ELECTRIC FAILURES OR JUST THE BLOWER ONLY?
6: SCAN THE pcM FOR ERRORS, AC IS CUT DEAD EVEN FOR ENGINE OVERHEATING OR OVERLOADED !!! OR IN LIMP MODE/
yah can't fix modern cars lacking a scan tool, no way./

bLOWER FACTS
PER THE SM BOOK REAL

THERE IS A BLOWER RELAY AND SOME FUSES. 12VDC SIDE.
FUSE 30 DASH
AND 21 HOOD, BOTH MUST BE GOOD. and fuse 12 V6
THE bLOWER gets GROUND FROM THIS
Audio-HVAC--Display Panel
l AND ITS BLOW POWER TRANSISTOR MODULE
SO WE KNOW THE TRANSISTOR IS off. IS CAUSE 1.
ONLY WHY REMAINS!!!!
YES THE CONTROLLER DOES NOT WANT TO RUN ANY DEAD BLOWER AND RISK ICE DAMAGE TO THE EVAP CORE.

THE Audio-HVAC Display Panel, READS MOTOR SPEED ACTUAL. speed (a kind blower tachometer wire)
IF SAY A INSECTS NEST JAMMED UP THE BLOWER FAN
THE AUDIO -HVAC, MODULE SEE THAT AND CUTS AC DEAD BY DESIGN AND HARD GOOD REASons/
the THE Audio-HVAC , has the ICE up sensor and monitors R134a
high/low switch and if wrong, tells the PCM to shut down its
Clutch solenoid to compressor ending all AC .
I am no sure what blower does.
but I can say this tell of blower works in heat mode or blower + no AC no HEAT mode. yes then the blower is not bad, nor the controller
what is wring is inputs to the controller are dead wrong
and not scanning the PCM after fuses is why you don't know.

l;earn now this works
Audio-HVAC
Display
Module
https://eautorepair.net/Marketing/Default.asp



not checking fuses first then scanning the PCm is why answers simple are not found.

like these and scads more.

Trouble Code: HVAC 12 (3.0L V6 VIN - Std)
A Problem in the Blower Motor Circuit

Trouble Code: HVAC 13 (3.0L V6 VIN - Std)
HVAC Control Unit Internal Error


Trouble Code: HVAC 14 (3.0L V6 VIN - Std)
An Open in the Evaporator Temperature Sensor Circuit (ICE Up preventions)

Trouble Code: HVAC 15 (3.0L V6 VIN - Std)
A Short in the Evaporator Temperature Sensor Circuit(ICE UP)



v6ac-undefined-undefined-0.jpg
0helpful
1answer

2003 trailblazer blower not working

Are you saying the blower motor would run intermittently and then just stopped working? My first thought is faulty blower motor, I've seen faulty blower motors that would run intermittently. Any motor that uses brushes, you can tap on the motor to see if it will start working, that is a sign of bad motor brushes, replace the blower motor. There could be other issues?
Did you check the blower fuse, not only check the fuse, check the fuse circuit for voltage, use a test light. Check for applicable hvac trouble codes. With hvac on, check for voltage and ground at blower motor wiring connector, if both are good and no blower action, suspect the blower motor.
blower motor-ah4hlr42fk2bjlxp04hurvgv-3-0.jpg
0helpful
1answer

2008 Mitsubishi Endeavor. Blower motor no longer works. Right before completely dying. If I would turn left I heard water flowing and blower barely worked. Now no water noise or fan working. Help plz

2004 Mitsubishi Endeavor AC transistor blower fix - YouTube

? 8:02
www.youtube.com/watch?v=6g_xozxuziE
Mar 19, 2015 - Uploaded by Peter Zafra
How to fix a Mitsubishi endeavor ac blower that stopped working. ... 2008 Mitsubishi Lancer HVAC Blower Motor Install How To - Duration: 9:07.
0helpful
1answer

HVAC BLOWER STOPPED WORKING

The noise can mean several things. It could be a bearing noise or something worked its way into the ductwork and jammed the motor. Without this noise, Ford products had problems with the blower motor resistor and that would be another prime candidate for failure.
You can take the blower motor out and have it benchchecked for electric problems.
2helpful
1answer

HVAC Blower stopped working

The fuse you replaced powers the hvac control. The run relay is powered by a 30amp fuse in the fuse box near the battery.
Is the relay getting power from that 30amp fuse ?
0helpful
1answer

HVAC Fan Blower Problem

sounds like the blower motor needs to be replaced.
1helpful
1answer

2001 T&C LXi - front blower fan is working intermittently

Hello! to answer your question; No...The intermittent operation is more than likely being caused by loose or oxidized contacts in the motor connector plug...Blower motor switch connector or the blower motor resistor plug...go to Radio Shack and purchase a product called DeOxit...cost $15...It's a two spray can package...A cleaner and contact protector spray...Cans are small you do not need much...Spray all three plugs; both male and female pins...You will notice a bubbling action...No wiping off...This is a no touch spray...This should clear up the problem...On the blower switch plug is a Black/Orange wire which goes to ground...Using an ohmmeter check this wire for zero ohms to ground...On the X10 scale...If you do not read zero ohms...The connection of this wire needs to go to bare metal chassis ground...

Guru...saailer

I’m happy to help further over the phone at https://www.6ya.com/expert/david_6df67de3b14de867

2helpful
1answer

The HVAC blower fan on my 2001 Pontiac Aztec stopped working on settings 1-3 several weeks ago. Last week it stopped working at setting 4 and today it stopped working all together. What is the most likely...

the blower not working on settings 1-3 is the blower motor resistor. this limits the power provided to the blower motor itself to change the speed. at setting 4 it is getting full power. since it quit on 4 also, i would still say the resistor needs to be replaced first, then see if the blower comes back. you may also need a blower motor. if you have a voltmeter you can just turn the switch to 4 and see if the motor is still getting 12 volts. if it is and doesn't run, it needs a blower motor too. if it's not, then its just the resistor
0helpful
1answer

Blower for Heat/AC

blower motor resistor is in the front (right?) wheel well.
Not finding what you are looking for?

1,337 views

Ask a Question

Usually answered in minutes!

Top Saturn Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

john h

Level 3 Expert

29494 Answers

Are you a Saturn Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...